ZHCSI11A August 2009 – April 2018 TXB0106-Q1
PRODUCTION DATA.
To begin the design process, determine the following:
• Input voltage range
- Use the supply voltage of the device that is driving the TXB0106-Q1 device to determine the input voltage range. For a valid logic high the value must exceed the VIH of the input port. For a valid logic low the value must be less than the VIL of the input port.
• Output voltage range
- Use the supply voltage of the device that the TXB0106-Q1 device is driving to determine the output voltage range.
- Avoid the use of external pullup or pulldown resistors, if possible. If not possible, it is recommended the value should be larger than 50 kΩ.
• An external pulldown or pullup resistor decreases the output VOH and VOL. Use the following equations to estimate the VOH and VOL as a result of an external pulldown and pullup resistor. See Effects of External Pullup and Pulldown Resistors on TXS and TXB Devices and Factors Affecting VOL for TXS and LSF Auto-bidirectional Translation Devices.
VOH = VCCx × RPD / (RPD + 4.5 kΩ)
VOL = VCCx × 4.5 kΩ / (RPU + 4.5 kΩ)
Where
• VCCx is the output port supply voltage on either VCCA or VCCB
• RPD is the value of the external pulldown resistor
• RPU is the value of the external pullup resistor
• 4.5 kΩ accounts for the tolerance of the serial 4-kΩ resistor in the I/O line.