ZHCSNM5C
november 2020 – august 2023
UCC25800-Q1
PRODUCTION DATA
1
1
特性
2
应用
3
说明
4
Revision History
5
Device Comparison Table
6
Pin Configuration and Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Power Management
8.3.2
Oscillator
8.3.3
External Synchronization
8.3.4
Dead-Time
8.3.4.1
Adaptive Dead-time
8.3.4.2
Maximum Programmable Dead-time
8.3.5
Protections
8.3.5.1
Overcurrent Protection
8.3.5.1.1
OCP Threshold Setting
8.3.5.1.2
Output Power Capability
8.3.5.2
Input Overvoltage Protection (OVP)
8.3.5.3
Over-Temperature Protection (TSD)
8.3.5.4
Pin-Fault Protections
8.3.5.5
VREG Pin Protection
8.3.6
DIS/FLT Pin operation
8.3.6.1
FAULT Codes
8.4
Device Functional Modes
8.4.1
UVLO Mode
8.4.2
Soft-start Mode
8.4.3
Normal Operation Mode
8.4.4
Disabled Mode
8.4.5
Fault Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
LLC Converter Operation Principle
9.2.2
Design Requirements
9.2.3
Detailed Design Procedure
9.2.4
Application Curves
9.3
What to Do and What Not to Do
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.2
接收文档更新通知
12.3
支持资源
12.4
Trademarks
12.5
静电放电警告
12.6
术语表
13
Mechanical, Packaging, and Orderable Information
封装选项
机械数据 (封装 | 引脚)
DGN|8
MPDS046G
散热焊盘机械数据 (封装 | 引脚)
DGN|8
PPTD362A
订购信息
zhcsnm5c_oa
zhcsnm5c_pm
9.3
What to Do and What Not to Do
Do
Good decoupling between VCC and GND, minimize the loop of VCC-GND and the decoupling capacitor
Use transformer with split chamber bobbin to minimize the EMI noise coupling from the inverter power stage
The UCC25800-Q1 transformer driver can be used to drive single higher power transformer or multiple lower power transformer
Setting the OCP1 level according to the designed load
Use post regulator if the voltage regulation requirement can't be met
Add Zener clamp at output if the output load can be completely removed
If cost is acceptable, use NP0 or C0G type resonant capacitor, or use X7R with much higher voltage rating than needed
Sufficient copper area for thermal management if the ambient temperature is high or the power level is high
Not to Do
Long VCC-GND decoupling capacitor trace
Set up the OCP1 to the highest level for all designs
千亿体育app官网登录(中国)官方网站IOS/安卓通用版/手机APP
|
米乐app下载官网(中国)|ios|Android/通用版APP最新版
|
米乐|米乐·M6(中国大陆)官方网站
|
千亿体育登陆地址
|
华体会体育(中国)HTH·官方网站
|
千赢qy国际_全站最新版千赢qy国际V6.2.14安卓/IOS下载
|
18新利网v1.2.5|中国官方网站
|
bob电竞真人(中国官网)安卓/ios苹果/电脑版【1.97.95版下载】
|
千亿体育app官方下载(中国)官方网站IOS/安卓/手机APP下载安装
|