ZHCSP86E May 2020 – February 2024 UCC5350-Q1
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
SUPPLY CURRENTS | ||||||
IVCC1 | Input supply quiescent current | 1.67 | 2.4 | mA | ||
IVCC2 | Output supply quiescent current | 1.1 | 1.8 | mA | ||
SUPPLY VOLTAGE UNDERVOLTAGE THRESHOLDS | ||||||
VIT+(UVLO1) | VCC1 Positive-going UVLO threshold voltage | 2.6 | 2.8 | V | ||
VIT– (UVLO1) | VCC1 Negative-going UVLO threshold voltage | 2.4 | 2.5 | V | ||
Vhys(UVLO1) | VCC1 UVLO threshold hysteresis | 0.1 | V | |||
OUTPUT SUPPLY VOLTAGE UNDERVOLTAGE THRESHOLDS (UCC5350MC-Q1) | ||||||
VIT+(UVLO2) | VCC2 Positive-going UVLO threshold voltage | 12 | 13 | V | ||
VIT–(UVLO2) | VCC2 Negative-going UVLO threshold voltage | 10.3 | 11 | V | ||
Vhys(UVLO2) | VCC2 UVLO threshold voltage hysteresis | 1 | V | |||
OUTPUT SUPPLY VOLTAGE UNDERVOLTAGE THRESHOLDS (UCC5350SB-Q1) | ||||||
VIT+(UVLO2) | VCC2 Positive-going UVLO threshold voltage | 8.7 | 9.4 | V | ||
VIT–(UVLO2) | VCC2 Negative-going UVLO threshold voltage | 7.3 | 8.0 | V | ||
Vhys(UVLO2) | VCC2 UVLO threshold voltage hysteresis | 0.7 | V | |||
LOGIC I/O | ||||||
VIT+(IN) | Positive-going input threshold voltage (IN+, IN–) | 0.55 × VCC1 | 0.7 × VCC1 | V | ||
VIT–(IN) | Negative-going input threshold voltage (IN+, IN–) | 0.3 × VCC1 | 0.45 × VCC1 | V | ||
Vhys(IN) | Input hysteresis voltage (IN+, IN–) | 0.1 × VCC1 | V | |||
IIH | High-level input leakage at IN+ | IN+ = VCC1 | 40 | 240 | µA | |
IIL | Low-level input leakage at IN– | IN– = GND1 | –240 | –40 | µA | |
IN– = GND1 – 5 V | –310 | –80 | ||||
GATE DRIVER STAGE | ||||||
VOH | High-level output voltage (VCC2 - OUT) and (VCC2 - OUTH) | IOUT = –20 mA | 100 | 240 | mV | |
VOL | Low level output voltage (OUT and OUTL) | IN+ = low, IN– = high; IOUT = 20 mA | 5 | 7 | mV | |
IOH | Peak source current | UCC5350MC, IN+ = high, IN– = low | 5 | 10 | A | |
UCC5350SB, IN+ = high, IN– = low | 5 | 8.5 | A | |||
IOL | Peak sink current | IN+ = low, IN– = high | 5 | 10 | A | |
Active Miller Clamp (UCC5350MC-Q1 only) | ||||||
VCLAMP | Low-level clamp voltage | ICLAMP = 20 mA | 7 | 10 | mV | |
ICLAMP | Clamp low-level current | VCLAMP = VEE2 + 15 V | 5 | 10 | A | |
ICLAMP(L) | Clamp low-level current for low output voltage | VCLAMP = VEE2 + 2 V | 5 | 10 | A | |
VCLAMP-TH | Clamp threshold voltage | 2.1 | 2.3 | V | ||
SHORT CIRCUIT CLAMPING | ||||||
VCLP-OUT | Clamping voltage (VOUT –VCC2) |
IN+ = high, IN– = low, tCLAMP = 10 µs, IOUT= 500 mA |
1 | 1.3 | V | |
VCLP-OUT | Clamping voltage ( VEE2 – VOUT) |
IN+ = low, IN– = high, tCLAMP = 10 µs, IOUT = –500 mA |
1.5 | V | ||
IN+ = low, IN– = high, IOUT = –20 mA |
0.9 | 1 | ||||
ACTIVE PULLDOWN | ||||||
VOUTSD | Active pulldown voltage on OUT | IOUT = 0.1 × IOUT(typ), VCC2 = open | 1.8 | 2.5 | V |