The 4-20 mA control-loop stability must be evaluated for any XTR11x design. A 10‑nF decoupling capacitor between V+ and IO is recommended for most applications. As this capacitance appears in parallel with the load resistance RLOAD from a stability perspective, the capacitor and resistor form a filter corner that can limit the bandwidth of the system. Therefore, for HART applications, use a bypass capacitance of 2 nF to 3 nF instead.
For applications with EMI and EMC concerns, use a bypass capacitor with sufficiently low ESR to decouple any ripple voltage from the VLOOP supply. Otherwise, the ripple voltage couples onto the 4‑mA to 20‑mA current source, and appears as noise across RLOAD after the current-to-voltage conversion.
Additionally, stability concerns apply to the VREF reference buffer when driving capacitive loads. Figure 8-4 shows that two filtering capacitors are required, one CHF of 10 pF to 0.5 µF and another CLF of 2.2 µF to 22 µF. Either a series isolation resistance RISO or a snubber RCOMP is used, depending on application requirements.