DLPU110B April   2021  – August 2022 DLPC6540

 

  1.   Programmer's Guide
  2.   Trademarks
  3. Scope
  4. References
  5. Acronyms
  6. System Boot
    1. 4.1 Data In flash
    2. 4.2 Bootloader Application
    3. 4.3 Main Application
    4. 4.4 Commands supported by Bootloader and Main Applications
    5. 4.5 Debug Terminal
    6. 4.6 HOST_IRQ/SYSTEM_BUSY
    7. 4.7 Heartbeat
    8. 4.8 Low-level Fault
  7. System Status
  8. Version
  9. Power Modes
  10. Display Modes
  11. Source Detection and Configuration
  12. 10Internal sources
    1. 10.1 Test Patterns (TPG)
    2. 10.2 Solid Field (SFG) Color
    3. 10.3 Curtain
  13. 11Display Formatting
  14. 12Image Processing
  15. 13Illumination Control
  16. 14Peripherals
    1. 14.1 GPIO
  17. 15Interface Protocol
    1. 15.1 Supported Interfaces
    2. 15.2 I2C Target
    3. 15.3 USB
  18. 16Command Protocol
    1. 16.1 Command Packet
    2. 16.2 Response Packet
    3. 16.3 Destination Details
    4. 16.4 Error Handling and Recovery
    5. 16.5 System Busy - I2C scenarios
      1. 16.5.1 GPIO implementation
      2. 16.5.2 Short Status response
    6. 16.6 Support for Variable Data Size
  19. 17Auto-Initilization Batch File
  20. 18Command Descriptions
  21. 19 System Commands
    1. 19.1  3D
    2. 19.2  Administrative
    3. 19.3  Autolock
    4. 19.4  Blending
    5. 19.5  Bootloader
    6. 19.6  Calibration
    7. 19.7  Debug Internal
    8. 19.8  Debug
    9. 19.9  General Operation
    10. 19.10 Illumination
    11. 19.11 Image Processing
    12. 19.12 Peripherals
    13. 19.13 Warping
    14. 19.14 Manual WPC
  22. 20Revision History

Illumination

Illumination

Table 19-90 Illumination Enable [Opcode: 80h | Destination: 4]
Set Illumination Enable
Write Parameter(s)
Byte Description
Byte 0

0 - Disabled

1 - Only Red LED Enabled

2 - Only Green LED Enabled

3 - Red and Green LEDs Enabled

4 - Only Blue LED Enabled

5 - Red and Blue LEDs Enabled

6 - Green and Blue LEDs Enabled

7 - All LEDs Enabled

Enables or Disables the illumination.

Get Illumination Enable
Data returned is in the same format as the Write Parameter(s).

Gets the enable state of illumination.

Table 19-91 DLPA3005 Illumination Current [Opcode: 84h | Destination: 4]
Set DLPA3005 Illumination Current
Write Parameter(s)
Byte Description
Bytes 0-1

Drive Level Red

Bytes 2-3

Drive Level Green

Bytes 4-5

Drive Level Blue

Sets DLPA3005 Drive Current Levels input as 10-bit Drive Level per LED in the range 0 - 874 (actual range is 0-1023 but the value is limited to reduce the changes of damaging reference LEDs). Command should not be used if Dynamic Black or White Point Correction is enabled.

Current output in Amps is calculated as described below.

OutputCurrent = ((DriveLevel + 1)/1024)*((0.15/0.004)) Amps

Example : For DriveLevel = 874; OutputCurrent = 32.04345703Amps

Note: Calculation is based on a max drive of 32A using 4mOhm RLIM resistor, refer to DLPA3005 datasheet to optimize for the LED being driven.

Get DLPA3005 Illumination Current
Data returned is in the same format as the Write Parameter(s).

Gets DLPA3005 Drive Current Levels.