SBAA287B May   2018  – December 2022 ADS114S06 , ADS114S06B , ADS114S08 , ADS114S08B

 

  1.   Understanding the Differences Between the ADS114S06 and ADS114S08 Standard and Cost-Optimized Versions
  2.   Trademarks
  3. 1Introduction
  4. 2Performance
  5. 3Features
  6. 4Specifications
  7. 5EVM Differences
  8. 6Alternative Device Recommendations
  9. 7Conclusion
  10. 8Revision History

Performance

The ADS114S06B and ADS114S08B have some relaxed specifications to help optimize cost and enable use in end-equipment that does not require the performance of the standard-grade ADCs. Table 2-1 summarizes these relaxed specifications and compares their values to the standard-grade devices.

Table 2-1 Performance Differences Between the ADS114S0x and ADS114S0xB
PARAMETERTEST CONDITIONSADS114S06
ADS114S08
ADS114S06B
ADS114S08B
UNIT
MINTYPMAXMINTYPMAX
Operating ambient temperature–50125–40125°C
Absolute input currentPGA enabled, all gains0.1±20.1±10nA
INL (best fit)PGA bypassed,
VCM = AVDD / 2
1101ppmFSR
PGA enabled, gain = 1 to 8, VCM = AVDD / 2215225
PGA enabled, gain = 16 to 128, VCM = AVDD / 2315225
Gain errorTA = 25°C, PGA bypassed0.004%0.012%0.01%0.1%
TA = 25°C, PGA enabled,
gain = 1 to 32
0.004%0.012%0.025%0.2%
TA = 25°C, PGA enabled,
gain = 64 and 128
0.004%0.02%0.025%0.2%
VREF accuracyTA = 25°C, TQFP package–0.05%±0.01%0.05%–0.2%±0.01%0.2%
TA = 25°C, QFN package–0.1%±0.01%0.1%–0.2%±0.01%0.2%
VREF temperature driftTA = –40°C to +85°C2.58840ppm/°C
TA = –50°C to +125°C310N/A
IDAC accuracy (each IDAC)TA = 25°C, 10 µA to 100 µA–5%±0.7%5%–6%±1%6%
TA = 25°C, 250 µA to 2 mA–3%±0.5%3%–6%±1%6%
IDAC current mismatchTA = 25°C, 10 µA to 100 µA0.15%0.8%0.20%
TA = 25°C, 250 µA to 750 µA0.1%0.6%0.20%
TA = 25°C, 1 mA to 2 mA0.07%0.4%0.20%
IDAC temperature drift10 µA to 750 µA20120100ppm/°C
1 mA to 2 mA1080100
IDAC temperature drift matching10 µA to 100 µA32510ppm/°C
250 µA to 2 mA21510
Oscillator accuracy–1.5%1.5%–2%2%
Device costADS114S06ADS114S06BUSD ($)
ADS114S08ADS114S08B