SBOA564A December   2022  – August 2024 TRF0206-SP

 

  1.   1
  2.   Single-Event Effects Test Report of the TRF0206-SP 6.5-GHz Differential Amplifier
  3.   Trademarks
  4. Overview
  5. Single-Event Effects
  6. Test Device and Evaluation Board Information
  7. Irradiation Facility and Setup
  8. Depth, Range, and LETEFF Calculation
  9. Test Set-Up and Procedures
  10. Single-Event Latch-up (SEL) Results
  11. Single-Event Transients (SET) Results
  12. Event Rate Calculations
  13. 10Summary
  14.   A Total Ionizing Dose from SEE Experiments
  15.   B Confidence Interval Calculations
  16.   C Orbital Environment Estimations
  17.   D References
  18.   E Revision History

Abstract

The effect of heavy-ion irradiation on the single-event effects performance of the TRF0206-SP high-performance, differential amplifier is summarized in this report. Heavy-ions with an LETEFF up to 82.1 MeV-cm2/mg were used to irradiate two production devices in multiple runs. Flux up to 105 ions/cm2-s and fluences up to 107 ions/cm2 at temperatures of 25°C (SET) and 125°C (SEL), were used for the characterization. Results demonstrate that the TRF0206-SP is SEL-free up to LETEFF = 82.1 MeV-cm2/mg and 125°C, and the cross section for the SET is discussed.