SBOK037B February 2019 – October 2020 INA901-SP
There were no functional failures at any irradiation level. All parametric measurements remained well within all INA901-SP Radiation Hardened, –15-V to 65-V Common Mode, Unidirectional Current-Shunt Monitor Data Sheet limits for all exposure levels. All parametric measurements remained well within the production test limits which are guard-banded from the data sheet limits. The full parameter list and graphs are found in Section A.
Table 4-1 lists the INA901-SP specification compliance matrix.
PARAMETER | TEST CONDITION | MIN | TYP | MAX | UNIT | TEST NUMBER |
---|---|---|---|---|---|---|
INPUT | ||||||
Common-mode rejection ratio | VIN+ = –16 V to 65 V | 80 | 120 | dB | 5.1 | |
Offset voltage | ±0.5 | ±2.5 | mV | 3.1 | ||
Vos vs power-supply | 5 | 250 | μV/V | 4.0 | ||
Input bias current, Vin-pin | ±8 | ±16 | μA | 7.2 | ||
OUTPUT | ||||||
Total gain error | VSENSE = 20 mV to 100 mV | ±0.2% | ±1.5% | 3.0 | ||
Total output error | ±0.75% | ±2% | 3.2 | |||
VOLTAGE OUTPUT | ||||||
Swing to V+ power-supply rail | (V+) – 0.05 | (V+) – 0.2 | V | 6.1 | ||
Swing to GND | VGND + 0.003 | VGND + 0.05 | V | 6.0 | ||
POWER SUPPLY | ||||||
Quiescent current | VOUT = 2 V | 700 | 900 | μA | 2.4 |