SBOK074 august   2023 SN54SC245-SEP

PRODUCTION DATA  

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Biased
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
  7. 4Reference Documents
  8. 5Appendix: HDR TID Report Data

Device Details

Table 1-1 lists the device information used for TID HDR characterization and qualification.

Table 1-1 Device and Exposure Details
TID HDR Details: up to 50 krad(Si)
TI Device NumberSN54SC245-SEP
Package20-pin PW (TSSOP)
TechnologyLBC9
Die Lot Number2113830RFB
A/T Lot Number and Date Code2CAH61K / 2249
Quantity Tested40 irradiated devices + 4control
Lot Accept or RejectDevices passed 30 krad(Si)
HDR Radiation FacilityTexas Instruments SLAB in Dallas, Texas
HDR Dose Level10 krad(Si), 20 krad(Si), 30 krad(Si), 50 krad(Si)
HDR Dose Rate264.5 -rad(Si)/s ionizing radiation
HDR Radiation SourceGammacell 220 Excel (GC-220E) Co-60
Irradiation TemperatureAmbient, room temperature