SBOU231 October 2020 OPA3S328
Figure 3-1 details the default jumper settings of the OPA3S328EVM. Table 3-1 explains the configuration for these jumpers.
Jumper | Function | Default Position | Description |
---|---|---|---|
J11 | V- Supply Select | Shunt 2-3 | Shunt 2–3: Selects AGND as V- for unipolar supply
configuration Shunt 1–2: Selects Ext V- supply for bipolar supply configuration |
J16 | Int DGND / Ext DGND: Site 1 | Shunt 1-2 | Site 1 internal or external DGND: Shunt 1–2: Selects internal DGND (AGND) Shunt 2–3: Selects external DGND |
J35 | Int DGND / Ext DGND: Site 2 | Shunt 1-2 | Site 2 internal or external DGND: Shunt 1–2: Selects internal DGND (AGND) Shunt 2–3: Selects external DGND |
J5 | -IN
Input | Open | Inverting input, amplifier A, site 1: Shunt 1–2: Selects external signal through SMA J4 Shunt 2–3: Selects AGND Open: Bias at Vsupply/2 |
J10 | Photodiode BIAS Amp A, Site 1 | Open | Photodiode bias, amplifier A, site 1: Shunt 1–2: Selects external bias through SMA J9 Shunt 2–3: Selects AGND Open: Bias at Vsupply/2 |
J6 | +IN Input Amp A, Site 1 | Open | Non-inverting input, amplifier A, site 1: Shunt 1–2: Selects external signal through SMA J7 Shunt 2–3: Selects AGND Open: Bias at Vsupply / 2 |
J18 | -IN Input Amp A, Site 2 | Open | Inverting input, amplifier A, site 2: Shunt 1–2: Selects external signal through SMA J17 Shunt 2–3 selects AGND Open: Bias at Vsupply/2 |
J21 | Photodiode BIAS Amp A, Site 2 | Open | Photodiode bias, amplifier A, site 2: Shunt 1–2: Selects external bias through SMA J19 Shunt 2–3: Selects AGND Open: Bias at Vsupply/2 |
J23 | +IN Input Amp A, Site 2 | Open | Non-inverting input, amplifier A, site 2: Shunt 1–2: Selects external signal through SMA J22 Shunt 2–3: Selects AGND Open: Bias at Vsupply / 2 |
J26 | -IN Input Amp B, Site 2 | Open | Inverting input, amplifier B, site 2: Shunt 1–2: Selects external signal through SMA J25 Shunt 2–3: Selects AGND Open: Bias at Vsupply/2 |
J28 | Photodiode BIAS Amp B, Site 2 | Open | Photodiode bias, amplifier B, site 2: Shunt 1–2: Selects external bias through SMA J27 Shunt 2–3: Selects AGND Open: Bias at Vsupply / 2 |
J34 | +IN Input Amp B, Site 2 | Open | Non-inverting input, amplifier B, site 2: Shunt 1–2: Selects external signal through SMA J33 Shunt 2–3: Selects AGND Open: Bias at Vsupply / 2 |
J12–J15 | Input select for switch matrix, Site 1 | J12 -
Open | Site 1 SELA0, SELA1, SELB0, SELB1: |
J29–J32 | Input select for switch matrix, Site 2 | J29 - Open J30 - Shunt J31 - Open J32 - Shunt | Site 1 SELA0, SELA1, SELB0, SELB1: Digital input pins for switch and shutdown control: Open: Low Shunt: High |
Table 3-2 details the select pin (SELxx) gain decoder for site 1 connections. For the special case with SELA0 = SELA1 = 1 (device on shutdown mode) decoder table, consult the OPA3S328 data sheet.
SELA1 |
SELA0 |
SELB1 | SELB0 J15 |
Switch Configuration, Gain |
---|---|---|---|---|
Low |
Low | Low (Open) | Low (Open) |
A1: Closed, A2:
Open B1: Closed, B2:
Open, B3:Open Selects feedback R4 (G = 200 kΩ) |
Low (Open) | High (Shunt) | Low (Open) | High (Shunt) |
A1: Open, A2:
Closed B1: Open,
B2:Closed, B3:Open Selects feedback R2 (G = 2 kΩ) |
High (Shunt) |
Low | High (Shunt) | Low (Open) |
A1: Open, A2:
Open B1: Open, B2:Open,
B3:Closed Selects default feedback R7 (R7 is Unpopulated) |
Table 3-3 details the select pin (SELxx) gain decoder for amplifier A site 2 connections. Table 3-4 shows the select pin (SELxx) gain decoder for amplifier B site 2 connections. For the select pin decoder special case with SELA0 = SELA1 = 1 (shutdown mode), consult the OPA3S328 data sheet.
SELA1 |
SELA0 |
Switch Configuration, Gain |
---|---|---|
Low |
Low |
A1: Closed, A2:
Open Selects feedback
R33 (20 kΩ, Switch A1) in parallel with default feedback R37
(200 kΩ) |
Low (Open) | High (Shunt) |
A1: Open, A2:
Closed Selects feedback
R30 (20 kΩ, Switch A2) in parallel with default feedback R37
(200 kΩ) |
High (Shunt) |
Low |
A1: Open, A2:
Open Selects feedback
default feedback R37 (200 kΩ) |
SELB1 |
SELB0 |
Switch Configuration, Gain |
---|---|---|
Low |
Low |
B1: Closed, B2:
Open, B3: Open Selects feedback
R61 |
Low (Open) | High (Shunt) |
B1: Open, B2:
Closed, B3: Open Selects feedback
R59 |
High (Shunt) |
Low |
B1: Open, B2:
Open, B3: Closed Selects feedback
R52 |
High (Shunt) | High (Shunt) |
B1: Open, B2:
Open, B3: Open Selects default feedback R49 (unpopulated, feedback Open) |