SBOU253 December   2020 LMH32404 , LMH32404-Q1

 

  1. 1Trademarks
  2. 2Introduction
    1. 2.1 Features
    2. 2.2 EVM Specifications
  3. 3Power Connections
  4. 4Input and Output Connections
    1. 4.1 Channel Multiplexer Mode Control
    2. 4.2 Input DC Current Cancellation
    3. 4.3 Enable Function
    4. 4.4 Optional VOCM Pin Connection
    5. 4.5 Option VOD Connection
  5. 5Board Layout
  6. 6Schematic and Bill of Materials
    1. 6.1 Bill of Materials
      1.      Related Documentation

Optional VOCM Pin Connection

The common-mode voltage of the differential outputs of all four amplifier channels can be controlled simultaneously using the test point (TP2) or optional resistor divider formed by R17 and R33. If left unconnected, the amplifier output common mode will default to 1.1 V. By default, the transformers on the EVM will AC couple the outputs of the device and remove the effect of the output common-mode voltage. The transformer must be removed and shorts installed between the transformer input and output pads to match the board to a device that requires DC outputs with a specified common mode (such as an analog to digital converter).