TID Characterization Summary Results

The parametric data for the SN54SC4T86-SEP passes to 30 krad(Si) HDR TID irradiation. The drifts of the electrical parameters through HDR were within the data sheet limits.

Overall, the SN54SC4T86-SEP showed a strong degree of hardness to HDR TID irradiation to 30 krad(Si). The measurements taken post-irradiation for each sample set showed a marginal shift for most parameters at each dose level. The parameters that did show a greater degree of change between pre- and post-irradiation were still within the electrical performance characteristics specified in the data sheet electrical parameters.

See Section 5 for HDR report to 30 krad(Si).