SFFS022 December 2022 TMS320F28384D , TMS320F28384D-Q1 , TMS320F28384S , TMS320F28384S-Q1 , TMS320F28386D , TMS320F28386D-Q1 , TMS320F28386S , TMS320F28386S-Q1 , TMS320F28388D , TMS320F28388S
The various redundancy architectures possible for the safety instrumented systems are indicated in Table A-1. For more information, see [10].
Diagnostic Implementation | ||
---|---|---|
1 | 1oo1 Architecture | NA |
2 | 1oo1D | Diagnostic channel is implemented using various hardware diagnostic features like Watchdog, and so forth. |
3 | 1oo1D Same figure as above. | Diagnostic channel is implemented using reciprocal comparison (uses two processing units for implementing reciprocal comparison) and other hardware diagnostic features. |
4 | 1oo2 | Two different processing units are used to implement one channel. |
5 | 2oo2 | Two different processing units are used to implement one channel. |
6 | 2oo2D | Two 1oo1D structures of #2 wired together to implement a safe channel. |
7 | 2oo2D Same figure as above. | Two 1oo1D structures of #3 wired together. |
8 | 1oo2D | Similar to 2oo2D implementation of #6 with additional control lines wired to control one set of units using the other unit |
9 | 1oo2D Same figure as above. | Similar to 2oo2D implementation of #7 with additional control lines wired to control one set of units using the other unit. |
10 | 2oo3 | Use three different processing units to implement majority voting. The fourth channel can be used either standalone or with hardware diagnostic features. |