SFFS027 January 2021 TPS62810M , TPS62811M , TPS62812M , TPS62813M
This section provides a Failure Mode Analysis (FMA) for the pins of the TPS6281xM. The failure modes covered in this document include the typical pin-by-pin failure scenarios:
Table 4-2 through Table 4-5 also indicate how these pin conditions can affect the device as per the failure effects classification in Table 4-1.
Class | Failure Effects |
---|---|
A | Potential device damage that affects functionality |
B | No device damage, but loss of functionality |
C | No device damage, but performance degradation |
D | No device damage, no impact to functionality or performance |
Figure 4-1 shows the TPS6281xM pin diagram. For a detailed description of the device pins please refer to the Pin Configuration and Functions section in the TPS6281xMdata sheet.
Following are the assumptions of use and the device configuration assumed for the pin FMA in this section:
Assumption the device is running in the typical application, please refer to the 'Simplified Schematics' on the
1st page in the TPS6281xMdatasheet.
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
MODE/SYNC | 1 | Normal operation | D |
VIN | 2 | Device does not power up, no output voltage | B |
SW | 3 | Potential device damage | A |
GND | 4 | Normal operation | D |
FB | 5 | 100% duty cycle mode, output voltage will follow the input voltage | B |
SS/TR | 6 | Device will not start properly, no output voltage | B |
COMP/FSET | 7 | Normal operation | D |
EN | 8 | Device is disabled, no output voltage | B |
PG | 9 | Normal operation, no power good indication | B |
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
MODE/SYNC | 1 | Device either operates in forced PWM or power save mode enabled, output voltage is regulated to its nominal value | B |
VIN | 2 | Device does not power up, no output voltage | B |
SW | 3 | No output voltage | B |
GND | 4 | Device does not power up, no output voltage | B |
FB | 5 | 100% or 0% duty cycle operation, no regulated output voltage. Output voltage will either follow the input voltage or no output voltage | B |
SS/TR | 6 | Normal operation | D |
COMP/FSET | 7 | Normal operation | D |
EN | 8 | Device is either enabled or disabled, if enabled output voltage is regulated to its nominal value, if disabled no output voltage | B |
PG | 9 | Normal operation | B |
Pin Name | Pin No. | Shorted to | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|---|
MODE/SYNC | 1 | 2 | Normal operation | D |
VIN | 2 | 3 | Potential device damage | A |
SW | 3 | 4 | Potential device damage | A |
GND | 4 | 5 | 100% duty cycle mode, output voltage will follow the input voltage | B |
FB | 5 | 6 | 0% duty cycle mode, no output voltage | B |
SS/TR | 6 | 7 | Normal operation | D |
COMP/FSET | 7 | 4 | Normal operation | D |
EN | 8 | 2 | Normal operation | D |
EN | 8 | 9 | Device does not power up, no output voltage | B |
PG | 9 | 1 | Device operates in forced PWM once PG is high impedance, output voltage is regulated to its nominal value | B |
Pin Name | Pin No. | Description of Potential Failure Effect(s) | Failure Effect Class |
---|---|---|---|
MODE/SYNC | 1 | Normal operation | D |
VIN | 2 | Normal operation | D |
SW | 3 | Potential device damage | A |
GND | 4 | Device does not power up, no output voltage | B |
FB | 5 | Potential device damage | A |
SS/TR | 6 | Normal operation | D |
COMP/FSET | 7 | Normal operation | D |
EN | 8 | Normal operation | D |
PG | 9 | Potential device damage | A |