SFFS169A April 2022 – May 2022 TPS3704 , TPS3704-Q1
In creating a functional Safety Element out of Context (SEooC) concept and doing the functional safety analysis, TI generates a series of assumptions on system level design, functional safety concept, and requirements. These assumptions (sometimes called Assumptions of Use) are listed below. Additional assumptions about the detailed implementation of safety mechanisms are separately located in Section 6.3.
The TPS3704x-Q1 Functional Safety Analysis was done under the following system assumptions:
TPS3704x-Q1 shall be considered in the safe state when no power is applied, or when operating in a fully functional and fault-free integrated system.
TPS3704x-Q1 shall be considered in a safe state when Over-Voltage (OV), Under-Voltage(UV), is detected on one or more sense inputs and signaled to an external host element of the system/item. The host is responsible for fault reaction and transitioning of the system to a system safe state.
During integration activities these assumptions of use and integration guidelines described for this component shall be considered. Use caution if one of the above functional safety assumptions on this component cannot be met, as some identified gaps may be unresolvable at the system level.