SFFS361 March   2022 TPSM82864A , TPSM82866A , TPSM82866C

 

  1.   Trademarks
  2. 1Overview
  3. 2Pin Failure Mode Analysis (Pin FMA)

Pin Failure Mode Analysis (Pin FMA)

This section provides a failure mode analysis (FMA) for the pins of the TPSM8286xA. The failure modes covered in this document include the typical pin-by-pin failure scenarios:

Table 2-2 through Table 2-5 also indicate how these pin conditions can affect the device as per the failure effects classification in Table 2-1.

Table 2-1 TI Classification of Failure Effects
ClassFailure Effects
APotential device damage that affects functionality.
BNo device damage, but loss of functionality.
CNo device damage, but performance degradation.
DNo device damage, no impact to functionality or performance.

Figure 2-1 shows the TPSM8286xA pin diagram. For a detailed description of the device pins, see the Pin Configuration and Functions section in the TPSM8286xA data sheet.

Figure 2-1 Pin Diagram

Following are the assumptions of use and the device configuration assumed for the pin FMA in this section:

  • The device is operating in the typical application, please refer to the Typical Application on the first page in the TPSM8286xA data sheet.
Table 2-2 Pin FMA for Device Pins Short-Circuited to Ground
Pin Name Pin No. Description of Potential Failure Effect(s) Failure Effect Class

EN

1

The device will not be enabled.

B

PG

2

Loss of PG functionality

B

VSET/MODE

3

Intended functionality for the adjustable output voltage configuration in power save mode. For the fixed output voltage configuration, the output voltage will be regulated to 0.6 V.

B

PGND

4, 5, 6, 8, 9, 10, 11, 19, 20

Intended functionality

D

SW

7

Potential device damage

A

VOUT

12, 13, 14, 15

No output voltage

B

VOS

16

No output voltage

B

FB

17

Output voltage will not be regulated. The device will enter 100% mode.

B

AGND

18

Intended functionality

D

VIN

21, 22

The device is not functional.

A

Table 2-3 Pin FMA for Device Pins Open-Circuited
Pin Name Pin No. Description of Potential Failure Effect(s) Failure Effect Class

EN

1

Undetermined state of the pin. The device may or may not be enabled.

B

PG

2

Loss of PG functionality

B

VSET/MODE

3

Will operate in forced PWM mode. If configured for the fixed output voltage configuration, the output voltage will be regulated to 0.6 V.

B

PGND

4, 5, 6, 8, 9, 10, 11, 19, 20

Redundant pin. If one of the pins are open, there is no functionality loss but there is a potential impact on device performance.

C

SW

7

Intended functionality

D

VOUT

12, 13, 14, 15

Redundant pin. If one of the pins are open, there is no functionality loss but there is a potential impact on device performance.

C

VOS

16

Output voltage regulation will be worse.

C

FB

17

The device is not functional. Open loop operation

B

AGND

18

The device is not functional.

B

VIN

21, 22

Redundant pin. If one of the pins are open, there is no functionality loss but there is a potential impact on device performance.

C

Table 2-4 Pin FMA for Device Pins Short-Circuited to Adjacent Pin
Pin Name Pin No. Shorted to Pin No. Description of Potential Failure Effect(s) Failure Effect Class

EN

1

PG

2

Loss of EN and PG functionality. Potential device damage

A

PG

2

VSET/MODE

3

Intended functionality for the adjustable output voltage configuration in power save mode. For the fixed output voltage configuration, the output voltage will be regulated to 0.6 V. If configured for forced PWM mode operation, there is potential device damage.

A

VSET/MODE

3

PGND

4

Intended functionality for the adjustable output voltage configuration in power save mode. For the fixed output voltage configuration, the output voltage will be regulated to 0.6 V. If configured for forced PWM mode operation, the device is not functional.

A

PGND

6

SW

7

Potential device damage

A

PGND

11

VOUT

12

No output voltage

B

VOUT

15

VOS

16

Intended functionality

D

VOS

16

FB

17

Intended functionality for the fixed output voltage configuration. For the adjustable output voltage configuration, the output voltage will be regulated to 0.6 V.

B

FB

17

AGND

18

Output voltage will not be regulated. The device will enter 100% mode.

B

AGND

18

PGND

19

Intended functionality

D

PGND

20

VIN

21

The device is not functional.

A

VIN

22

EN

1

Loss of EN functionality

B

Table 2-5 Pin FMA for Device Pins Short-Circuited to VIN
Pin Name Pin No. Description of Potential Failure Effect(s) Failure Effect Class

EN

1

Loss of EN functionality

B

PG

2

Loss of PG functionality. Potential device damage

A

VSET/MODE

3

Intended functionality for the adjustable output voltage configuration in forced PWM mode. For the fixed output voltage configuration, the output voltage will be regulated to 0.6 V.

B

PGND

4, 5, 6, 8, 9, 10, 11, 19, 20

The device is not functional.

A

SW

7

Potential device damage

A

VOUT

12, 13, 14, 15

Potential device damage

A

VOS

16

Potential device damage

A

FB

17

Output voltage will not be regulated. If configured in forced PWM mode, there is potential device damage.

A

AGND

18

The device is not functional.

A

VIN

21, 22

Intended functionality

D