SFFS578A February   2023  – January 2024 INA241A-Q1 , INA241B-Q1 , INA296A-Q1 , INA296B-Q1

 

  1.   1
  2.   Trademarks
  3. 1Overview
  4. 2Functional Safety Failure In Time (FIT) Rates
    1. 2.1 DDF-8, DGK-8, DGS-10 and D-8 Packages
  5. 3Failure Mode Distribution (FMD)
  6. 4Pin Failure Mode Analysis (Pin FMA)
    1. 4.1 DDF-8, DGK-8 and D-8 Packages
    2. 4.2 DGS-10 Package
  7. 5Revision History

DGS-10 Package

Figure 4-2 shows the INA241x-Q1 and INA296x-Q1 pin diagram for the DGS-10 package. For a detailed description of the device pins, see the Pin Configuration and Functions section in the INA241x-Q1 and INA296x-Q1 data sheet.

Figure 4-2 Pin Diagram (DGS-10 Package)
Table 4-6 Pin FMA for Device Pins Short-Circuited to Ground
Pin Name Pin No. Description of Potential Failure Effects Failure Effect Class
IN- 1 In high-side configuration, a short from the bus supply to GND will occur. High current will flow from bus supply to ground. In low side configuration, normal operation. B for high side or D for low side
NC 2 This pin has no internal connection. Normal operation. D
GND 3 Normal operation. D
REF2 4 If intended connection is anything other than GND, functionality will be affected. D if REF2=GND by design; B otherwise
NC 5 Normal operation. D
OUT 6 Output shorts to ground. B
Vs 7 Power supply shorted to ground. B
REF1 8 If intended connection is anything other than GND, functionality will be affected. D if REF1 = GND by design; B otherwise
NC 9 This pin has no internal connection. Normal operation. D
IN+ 10 In high-side configuration, a short from the bus supply to GND will occur. High current will flow from bus supply to ground. In low side configuration, input pins are shorted. B
Table 4-7 Pin FMA for Device Pins Open-Circuited
Pin Name Pin No. Description of Potential Failure Effects Failure Effect Class
IN- 1 IN- will be at the same potential as IN+. Differential input voltage is effectively 0V. B
NC 2 This pin has no internal connection. Normal operation. D
GND 3 GND is floating. Output will be incorrect as it is no longer referenced to GND. B
REF2 4 Device loses reference voltage. B
NC 5 This pin has internal weak pull down. Even though possible, the likelihood of malfunction is low. D
OUT 6 Output can be left open. There is no effect on the IC. C
Vs 7 No power supply to device. Device may be biased through inputs. Output will be close to GND. B
REF1 8 Device loses reference voltage. B
NC 9 This pin has no internal connection. Normal operation. D
IN+ 10 IN+ will be at the same potential as IN-. Differential input voltage is effectively 0V. B
Table 4-8 Pin FMA for Device Pins Short-Circuited to Adjacent Pin
Pin Name Pin No. Shorted to Description of Potential Failure Effects Failure Effect Class
IN- 1 NC Normal operation. D
NC 2 GND Normal operation. D
GND 3 REF2 If intended connection is anything other than GND, functionality will be affected. D if REF2 = GND by design; B otherwise
REF2 4 NC Functionality will be affected if REF2 equals to anything but GND by design. C
NC 5 OUT Changing output may affect functionality, but the likelihood is very low. C
OUT 6 Vs Output shorts to supply. B
Vs 7 REF1 Functionality will be affected if REF1 equals to anything but Vs by design. D if REF1 = Vs by design; B otherwise
REF1 8 NC Normal operation. D
NC 9 IN+ Normal operation. D
IN+ 10 IN- Input differential voltage = 0V B
Table 4-9 Pin FMA for Device Pins Short-Circuited to supply
Pin Name Pin No. Description of Potential Failure Effects Failure Effect Class
IN- 1 In high-side configuration, a short from the bus supply to Vs will occur. High current will flow from bus supply to Vs or vice versa. Device could be damaged. A for high side or B for low side
NC 2 This pin has no internal connection. Normal operation. D
GND 3 Power supply shorted to GND. B
REF2 4 If intended connection is anything other than Vs, functionality will be affected. D if REF2 = Vs by design; B otherwise
NC 5 Additional small amount of current is drawn by the pull down resistor. C
OUT 6 Output shorts to supply. B
Vs 7 Normal operation. D
REF1 8 If intended connection is anything other than Vs, functionality will be affected. D if REF1 = Vs by design; B otherwise
NC 9 This pin has no internal connection. Normal operation. D
IN+ 10 In high-side configuration, a short from the bus supply to Vs will occur. High current will flow from bus supply to Vs or vice versa. Device could be damaged. A for high side or B for low side