SLAA351A April 2007 – November 2018 MSP430F2232 , MSP430F2232 , MSP430F2234 , MSP430F2234 , MSP430F2252 , MSP430F2252 , MSP430F2254 , MSP430F2254 , MSP430F2272 , MSP430F2272 , MSP430F2274 , MSP430F2274
If none of the false flags are set, then a glass-breakage detect is issued. This immediately enables the buzzer and the LED for indication. The buzzer is turned on for a period of three seconds and then turned off. The device then goes back into its wake-up mode settings and is ready for the next detection.