SLAA954 August 2020 – MONTH TAS2563
Define the Pass/Fail Limits of each parameter based on the speaker datasheet tolerance or on the application requirement. Select “Next” to generate the binary, ftcfg, cfg, and header files
In some cases, if the speaker parameter tolerances are not defined in the speaker datasheet, it is recommended to use Re variation as the limits for Re, and 6-Sigma deviation of Re variation as the variation limits for the rest of the speaker parameters