SLAU654E November 2015 – February 2019
Table 3 lists the possible error codes and messages.
Error Code | Error Message |
---|---|
0 | No error |
1 | Could not initialize device interface |
2 | Could not close device interface |
3 | Invalid parameter(s) |
4 | Could not find device (or device not supported) |
5 | Unknown device |
6 | Could not read device memory |
7 | Could not write device memory |
8 | Could not read device configuration fuses |
9 | Incorrectly configured device; device derivative not supported |
10 | Could not set device Vcc |
11 | Could not reset device |
12 | Could not preserve/restore device memory |
13 | Could not set device operating frequency |
14 | Could not erase device memory |
15 | Could not set device breakpoint |
16 | Could not single step device |
17 | Could not run device (to breakpoint) |
18 | Could not determine device state |
19 | Could not open Enhanced Emulation Module |
20 | Could not read Enhanced Emulation Module register |
21 | Could not write Enhanced Emulation Module register |
22 | Could not close Enhanced Emulation Module |
23 | File open error |
24 | File type could not be identified |
25 | File end error |
26 | File input/output error |
27 | File data error |
28 | Verification error |
29 | Could not secure the device |
30 | The Debug Interface to the device has been secured |
31 | Error within Intel Hex file |
32 | Could not write device Register |
33 | Could not read device Register |
34 | Not supported by selected Interface or Interface is not initialized |
35 | Interface Communication error |
36 | No external power supply detected |
37 | External power too low |
38 | External power detected |
39 | External power too high |
40 | Hardware Self Test Error |
41 | Fast Flash Routine experienced a timeout |
42 | Could not create thread for polling |
43 | Could not initialize Enhanced Emulation Module |
44 | Insufficient resources |
45 | No clock control emulation on connected device |
46 | No state storage buffer implemented on connected device |
47 | Could not read trace buffer |
48 | Enable the variable watch function |
49 | No trigger sequencer implemented on connected device |
50 | Could not read sequencer state - Sequencer is disabled |
51 | Could not remove trigger - Used in sequencer |
52 | Could not set combination - Trigger is used in sequencer |
53 | System Protection Module A is enabled - Device locked |
54 | Invalid SPMA key was passed to the target device - Device locked |
55 | Device does not accept any further SPMA keys - Device locked |
56 | MSP-FET430UIF Firmware erased - Bootloader active |
57 | Could not find MSP-FET430UIF on specified COM port |
58 | MSP-FET430UIF is already in use |
59 | EEM polling thread is already active |
60 | Could not terminate EEM polling thread |
61 | Could not unlock BSL memory segments |
62 | Could not perform access, BSL memory segments are protected |
63 | Another device as selected was found |
64 | Could not enable JTAG wrong password |
65 | Only one UIF must be connected during update to v3 |
66 | CDC-USB-FET-Driver was not installed. Please install the driver |
67 | Manual reboot of USB-FET needed ! PLEASE unplug and reconnect your USB-FET!! |
68 | Internal error |
69 | One of the connected MSP-FETs / eZ-FETs debuggers needs recovery |
70 | One of the connected MSP-FETs / eZ-FETs debuggers needs recovery |
71 | Feature not supported |
72 | Only one MSP-FET / eZ-FET must be connected during recovery |
73 | MSP-FET / eZ-FET recovery failed |
74 | MSP-FET / eZ-FET core(communication layer) update failed |
75 | MSP-FET / eZ-FET legacy module update failed |
76 | EnergyTrace is not supported by the selected debugger |
77 | Hardware State is unknown |
78 | Device configuration data inconsistent. Please discontinue using/replace target device. |
79 | EEM module not accessible while running in Ultra Low Power Debug Mode - Deactivate Ultra Low Power Debug mode to enable this feature |
80 | Failed to remove software breakpoints, please reprogram target device |
81 | Trigger configuration conflicts with existing triggers |
82 | Operation not possible while device is running |
83 | This function can not be used when software breakpoints are enabled |
84 | JTAG/SBW speed configuration failed |
85 | Software breakpoint can't be set (followed by critical value) |
86 | EnergyTrace is not supported by selected MSP430 device |
87 | EnergyTrace requires Ultra-Low Power debug / LPMx.5 enabled |
88 | Legacy version of silicon used, which is no longer supported. Please contact TI to obtain a newer version. |
89 | Secure device via the IDE is not supported. See Device User Guide for further information. |
90 | Cycle counter is in basic mode. Set to advanced mode to use this function. |
91 | Parallel port FET (MSP-FETP430IF) is no longer supported. |
92 | Wrong target architecture was selected - Valid architectures are MSP430 or MSP432_M4. |
93 | Mass erase executed. Please power-cycle your device and restart the debug session. |
94 | Your connected hardware might drain too much power from the debugger.This results in an overcurrent. |
95 | MSP Tool firmware update failed. Please ensure the USB or Backchannel UART connection is not in use. |
96 | MSP432 devices are not supported using the MSPFET430-UIF |
97 | DAP is locked or wrong debug protocol selected. |
98 | Device database not loaded. |
99 | Invalid error number |