10.5.22 ADCSSTSH0 Register (Offset = 0x5C) [reset = 0x0]
ADC Sample Sequence 0 Sample and Hold Time (ADCSSTSH0)
This register controls the sample period size for each sample of sequencer 0. Each sample and hold period select specifies the time allocated to the sample and hold circuit as shown by the encodings inTable 10-2.
NOTE
If sampling the internal temperature sensor, the sample and hold width should be at least 16 ADC clocks (TSHn = 0x4).
Table 10-29 Sample and Hold Width in ADC Clocks
TSHn Encoding |
NSH |
0x0 |
4 |
0x1 |
Reserved |
0x2 |
8 |
0x3 |
Reserved |
0x4 |
16 |
0x5 |
Reserved |
0x6 |
32 |
0x7 |
Reserved |
0x8 |
64 |
0x9 |
Reserved |
0xA |
128 |
0xB |
Reserved |
0xC |
256 |
0xD to 0xF |
Reserved |
ADCSSTSH0 is shown in Figure 10-36 and described in Table 10-30.
Return to Summary Table.
Figure 10-36 ADCSSTSH0 Register
31 |
30 |
29 |
28 |
27 |
26 |
25 |
24 |
23 |
22 |
21 |
20 |
19 |
18 |
17 |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
TSH7 |
TSH6 |
TSH5 |
TSH4 |
TSH3 |
TSH2 |
TSH1 |
TSH0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
|
Table 10-30 ADCSSTSH0 Register Field Descriptions
Bit |
Field |
Type |
Reset |
Description |
31-28 |
TSH7 |
R/W |
0x0 |
8th Sample and Hold Period Select.
The TSH7 field is used during the eighth sample of a sequence executed with the sample sequencer. |
27-24 |
TSH6 |
R/W |
0x0 |
7th Sample and Hold Period Select.
The TSH6 field is used during the seventh sample of a sequence executed with the sample sequencer. |
23-20 |
TSH5 |
R/W |
0x0 |
6th Sample and Hold Period Select.
The TSH5 field is used during the sixth sample of a sequence executed with the sample sequencer. |
19-16 |
TSH4 |
R/W |
0x0 |
5th Sample and Hold Period Select.
The TSH4 field is used during the fifth sample of a sequence executed with the sample sequencer. |
15-12 |
TSH3 |
R/W |
0x0 |
4th Sample and Hold Period Select.
The TSH3 field is used during the fourth sample of a sequence executed with the sample sequencer. |
11-8 |
TSH2 |
R/W |
0x0 |
3rd Sample and Hold Period Select.
The TSH2 field is used during the third sample of a sequence executed with the sample sequencer. |
7-4 |
TSH1 |
R/W |
0x0 |
2nd Sample and Hold Period Select.
The TSH1 field is used during the second sample of a sequence executed with the sample sequencer. |
3-0 |
TSH0 |
R/W |
0x0 |
1st Sample and Hold Period Select.