SLAU723A October 2017 – October 2018 MSP432E401Y , MSP432E411Y
Bus Fault Address (FAULTADDR)
NOTE
This register can only be accessed from privileged mode.
The FAULTADDR register contains the address of the location that generated a bus fault. When an unaligned access faults, the address in the FAULTADDR register is the one requested by the instruction, even if it is not the address of the fault. Bits in the Bus Fault Status (BFAULTSTAT) register indicate the cause of the fault and whether the value in the FAULTADDR register is valid (seeSection 2.5.12).
FAULTADDR is shown in Figure 2-27 and described in Table 2-40.
Return to Summary Table.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
ADDR | |||||||||||||||||||||||||||||||
R/W-X | |||||||||||||||||||||||||||||||