4.2.86 RCGCTIMER Register (Offset = 0x604) [reset = 0x00]
16/32-Bit General-Purpose Timer Run Mode Clock Gating Control (RCGCTIMER)
The RCGCGPT32 register lets software enable and disable 16/32-bit timer modules in run mode. When enabled, a module is provided a clock, and accesses to module registers are allowed. When disabled, the clock is disabled to save power, and accesses to module registers generate a bus fault.
NOTE
This register controls the clocking for the timer modules.
RCGCTIMER is shown in Figure 4-92 and described in Table 4-99.
Return to Summary Table.
Figure 4-92 RCGCTIMER Register
31 |
30 |
29 |
28 |
27 |
26 |
25 |
24 |
23 |
22 |
21 |
20 |
19 |
18 |
17 |
16 |
RESERVED |
R-0x0 |
|
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
RESERVED |
R7 |
R6 |
R5 |
R4 |
R3 |
R2 |
R1 |
R0 |
R-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
R/W-0x0 |
|
Table 4-99 RCGCTIMER Register Field Descriptions
Bit |
Field |
Type |
Reset |
Description |
31-8 |
RESERVED |
R |
0x0 |
|
7 |
R7 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 7 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 7 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 7 in run mode.
|
6 |
R6 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 6 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 6 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 6 in run mode.
|
5 |
R5 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 5 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 5 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 5 in run mode.
|
4 |
R4 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 4 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 4 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 4 in run mode.
|
3 |
R3 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 3 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 3 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 3 in run mode.
|
2 |
R2 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 2 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 2 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 2 in run mode.
|
1 |
R1 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 1 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 1 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 1 in run mode.
|
0 |
R0 |
R/W |
0x0 |
16/32-Bit General-Purpose Timer 0 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 0 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer module 0 in run mode.
|