The PWM module provides four PWM generators, each providing two PWM outputs that may be used in a wide variety of applications. Generally speaking, the PWM is used in one of two categories of operation:
The PWM generator and its two output signals are used alone, independent of other PWM generators.
The PWM generator and its two outputs signals are used in conjunction with other PWM generators using a common, unified time base. If multiple PWM generators are configured with the same counter load value, synchronization can be used to guarantee that they also have the same count value (the PWM generators must be configured before they are synchronized). With this feature, more than two MnPWMn signals can be produced with a known relationship between the edges of those signals because the counters always have the same values. Other states in the module provide mechanisms to maintain the common time base and mutual synchronization.
The counter in a PWM generator can be reset to zero by writing the PWM Time Base Sync (PWMSYNC) register and setting the SYNCn bit associated with the generator. Multiple PWM generators can be synchronized together by setting all necessary SYNCn bits in one access. For example, setting the SYNC0 and SYNC1 bits in the PWMSYNC register causes the counters in PWM generators 0 and 1 to reset together.
Additional synchronization can occur between multiple PWM generators by updating register contents in one of the following three ways:
The following registers provide either local or global synchronization based on the state of various Update mode bits and fields in the PWMnCTL register (LOADUPD, CMPAUPD, and CMPBUPD):
The following registers default to immediate update, but are provided with the optional functionality of synchronously updating rather than having all updates take immediate effect:
All other registers are considered statically provisioned for the execution of an application or are used dynamically for purposes unrelated to maintaining synchronization and therefore do not need synchronous update functionality.