SLAZ742A July   2023  – October 2023 MSPM0G1105 , MSPM0G1106 , MSPM0G1107 , MSPM0G1505 , MSPM0G1506 , MSPM0G1507 , MSPM0G3105 , MSPM0G3105-Q1 , MSPM0G3106 , MSPM0G3106-Q1 , MSPM0G3107 , MSPM0G3107-Q1 , MSPM0G3505 , MSPM0G3505-Q1 , MSPM0G3506 , MSPM0G3506-Q1 , MSPM0G3507 , MSPM0G3507-Q1

 

  1.   1
  2.   Abstract
  3. 1Functional Advisories
  4. 2Preprogrammed Software Advisories
  5. 3Debug Only Advisories
  6. 4Fixed by Compiler Advisories
  7. 5Device Nomenclature
  8. 6Advisory Descriptions
    1. 6.1  ADC_ERR_01
    2. 6.2  ADC_ERR_02
    3. 6.3  BSL_ERR_01
    4. 6.4  COMP_ERR_02
    5. 6.5  COMP_ERR_03
    6. 6.6  CPU_ERR_01
    7. 6.7  GPIO_ERR_01
    8. 6.8  I2C_ERR_01
    9. 6.9  I2C_ERR_02
    10. 6.10 I2C_ERR_03
    11. 6.11 PWREN_ERR_01
    12. 6.12 RTC_ERR_01
    13. 6.13 SPI_ERR_01
    14. 6.14 SPI_ERR_02
    15. 6.15 SYSOSC_ERR_01
    16. 6.16 TIMER_ERR_01
    17. 6.17 VREF_ERR_01
    18. 6.18 WWDT_ERR_01
    19. 6.19 WWDT_ERR_02
  9. 7Revision History

ADC_ERR_02

Increased current in low power mode when ADC is in Repeat mode

Revisions Affected

Rev B

Details

When the ADC is configured to Repeat Sequence or Repeat Single mode with EVENT trigger in low power mode (LPM), the ADC module will consume additional current until disabled.

Workaround

Configure ADC to be in Single or Sequence mode (no Repeat), and use an interrupt after conversion to re-enable ADC for next trigger