SLLU321 July 2022
Configure the TCAN1043A-Q1 EVM for normal operation by installing shunts on the EVM as described in Table 3-1.
Jumper | Shunt |
---|---|
JMP3 | Installed – implements 120-Ω resistor between CANH and CANL |
JMP5 | Installed – implements 120-Ω resistor between CANH and CANL |
JMP6 | Installed – shorts VCC and VIO
together Use P2 to drive VIO independently from VCC |
Connect the power supplies to the EVM using the banana connecter P1, P2, P3, and P4. If banana cables are unavailable, use test points TP11, TP12, TP13, TP14, TP15, and TP16 instead.
For more detailed information, see the schematic reference for power in Figure 4-1.
Connect the EVM to the CAN bus for network evaluation. TXD and RXD can be jumper connected to the CAN controller through JMP2 position 1 and position 3, respectively. If evaluating the TCAN1043A-Q1 without a CAN network, connect a function generator to JMP2 position 1 with the desired data rate. The generator should be set to provide a 0 V to 5 V TTL square wave into the high impedance input TXD. Connect an oscilloscope with high-impedance probes or high-impedance input to the CAN bus line CANH and CANL. Use a third channel on the oscilloscope to monitor RXD.