To test these features on the
TUSB217AEVM-BC:
- Remove the 0-Ω resistor
connecting the upstream VBUS and the EVM power (R1, R16, R31).
- Externally power the EVM, by
providing power to pin 1 of the 6 × 2 header (VCC_EXT_Px). This power source
should be able to provide up to 1.5 A at 5 V DC. TI recommends setting the
voltage slightly above 5 V to prevent droop issues.
- There is an VBUS toggle circuit
on the EVM that should provide an adequate VBUS toggle to force connected
downstream devices to disconnect and reconnect when transitioning between CDP
and DCP mode in most cases. This toggle length will vary depending on the
voltage and bulk capacitance of the system, and may not work for all
applications. If it does not, see Manual DCP/CDP Test Setup.
- Verify that the charging device
power consumption is as expected.