The UCC28070 external synchronization facilitates using more than two phases for interleaving. Multiple UCC28070s can easily be paralleled to add an even number of additional phases for higher-power applications. An odd number of phases can be accommodated, however, an even number of phases are recommended due to the optimal ripple current cancellation at 50% duty cycle. With two phases per controller, for 2- 4- or 6-phase solution, each controller should receive a SYNC signal which is 360/n degrees out of phase with each other (where n = the number of UCC28070 controllers). With appropriate phase-shifting of the synchronization signals, even more input and output ripple current cancellation can be obtained.
For a 4-phase interleaved application with two controllers, SYNC1 should be 180° out of phase with SYNC2 for optimal ripple cancellation. Similarly for a 6-phase system, SYNC1, SYNC2, and SYNC3 should be 120° out of phase with each other for optimal ripple cancellation. Figure 2-1 illustrates the paralleling of two controllers for a four-phase 90-degree-interleaved PFC system. However, because the UCC28064A does not have a synchronization feature like the UCC28070, it is not as straightforward to parallel multiple controllers.