SLUAAJ7 June 2022 UCC256402 , UCC256403 , UCC256404
UCC256402 | UCC256402A | UCC256403 | UCC256403A | UCC256404 | UCC256404A | UCC256404B | |
---|---|---|---|---|---|---|---|
Key Application | Lighting/Industrial | Lighting/Industrial | TV OLED Screen/Telecom/Industrial | TV OLED Screen/Telecom/Industrial | TV - WLLC | TV - WLLC | TV - WLLC |
Burst Packet Size | 16 | 16 | 40 | 16 | 40 | 16 | 40 |
Burst Soft On/Off | No | No | Yes | No | Yes | No | Yes |
HV Startup | Yes | Yes | No | No | Yes | Yes | Yes |
Auxiliary Supply Required | No | No | Yes | Yes | No | No | No |
X-Cap Discharge (XCD) | No | No | No | No | Yes | Yes | Yes |
BLK/DC Start (1) | 3 V/340 V | 3 V/340 V | 3 V/340 V | 3 V/340 V | 1 V/113 V | 1 V/113 V | 1 V/113 V |
BLK/DC Stop (1) | 2.2 V/249 V | 2.2 V/249 V | 2.2 V/249 V | 2.2 V/249 V | 0.9 V/102 V | 0.9 V/102 V | 0.9 V/102 V |
BLK/DC OVP (1) | NA | 4 V/453 V | NA | NA | NA | NA | NA |
BW OVP Mode | Restart | Restart | Restart | Latch | Restart | Latch | Restart |
Other Fault Mode | Restart | Restart | Restart | Restart | Restart | Restart | Restart |
PFC Off in Standby Mode | No | No | No | No | Yes | Yes | Yes |
VCC startup voltage that will initiate startup process | 26 V | 26 V | 10.9 V | 10.9 V | 26 V | 26 V | 26 V |
The UCC256404B maximum XCD test current is lower (1.3mA) compared to the maximum XCD test currents of the 404 and 404A (1.7mA). This difference helps to reduce stand-by power loss when using the UCC256404B during very-light-load to no-load conditions.