SLUK023A February   2019  – June 2024 UC1825B-SP

 

  1.   1
  2.   UC1825B-SP total ionizing dose (TID) radiation report
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Conditions
  6. 3TID Characterization Results
    1. 3.1 Device Spec Table
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   LDR TID Report
  9.   B Revision History

Test Overview

The UC1825B-SP is tested according to MIL-STD-883J, Test Method 1019.9. For this testing, Condition D is used. For this test, the product is irradiated up to the rated radiation level and then put through full electrical parametric testing on the production Automated Test Equipment (ATE). The device is functional through the testing and passed all parametric tests (within guard bands) of the Standard Microcircuit Drawing (SMD) electrical specification limits.