SLUK023A February   2019  – June 2024 UC1825B-SP

 

  1.   1
  2.   UC1825B-SP total ionizing dose (TID) radiation report
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Conditions
  6. 3TID Characterization Results
    1. 3.1 Device Spec Table
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   LDR TID Report
  9.   B Revision History

Device Spec Table

Table 3-1 lists the device data sheet along with the corresponding ATE test that accompanies it.

Table 3-1 UC1825B-SP Spec Table
PARAMETERTEST CONDITIONSLUSDD5TEST # OR NAME
REFERENCE
Output voltageTJ = 25°C, IO = 1mA5.025.105.18V1015.2__VREF_15 V_1 mA
1015.3__VREF_30 V_1 mA
1015.4__VREF_15 V_10 mA
1015.5__VREF_30 V_10 mA
Line regulation10V < VCC < 30V220mV1015.6__VREF_Line_Reg
Load regulation1mA < IO < 10mA520mV1015.7__VREF_Load_Reg
OSCILLATOR SECTION
Initial accuracyTJ = 25°C360400440kHz1020.1__Osc_Freq @ 15 V
1020.1__Osc_Freq @ 30 V
ERROR AMPLIFIER
Input offset voltage10mV1025.1__Vio
SOFT_START
Charge currentVSoftStart = 0.5V3920µA1040.1__Charge Current
Discharge currentVSoftStart = 1 V1µA1040.2__Discharge Current
OUTPUT
Low-level output voltageIOUT = 20mA.25.40V1045.2__VOL(OUTA) @ 20 mA
1045.4__VOL(OUTB) @ 20 mA
IOUT = 200mA1.22.2V1045.3 __VOL(OUTA) @ 200 mA
1045.5__VOL(OUTB) @ 200 mA
High-level output voltageIOUT = -20mA13.013.5V1045.8__VOH(OUTB) @ 20 mA
1045.10__VOH(OUTA) @ 20 mA
IOUT = -200mA12.013.0V1045.9__VOH(OUTB) @ 200 mA
1045.11__VOH(OUTA) @ 200 mA
UNDER-VOLTAGE LOCKOUT
Start threshold8.89.29.6V1010.5__VV UVLO ON
UVLO hysteresis0.40.81.2V1010.&__UVLO Hysteresis
SUPPLY CURRENT SECTION
Startup currentVCC = 8V1.12.5mA1010.1__ICC @ 8 V
ICCVINV = VRamp = VILIM/SD = 0V, VNI = 1V2233mA1010.3__ICC @ 15 V