SLUSAM9E July 2011 – April 2020
PRODUCTION DATA.
PARAMETER | TEST CONDITION | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
GVCOUT | Cell voltage amplifier gain | Measured from VCn
to VCOUT |
REF_SEL = 0 | –1.6% | 0.3 | 1.5% | |
REF_SEL = 1 | –1.6% | 0.6 | 1.5% | ||||
OVCOUT | Cell voltage amplifier offset | Measured from VCn to VCOUT | –16 | 15 | mV | ||
VCOUT | Cell voltage amp output range (1) | Measured at VCOUT,
VCn = 5 V |
REF_SEL = 0 | 1.47 | 1.5 | 1.53 | V |
REF_SEL = 1 | 2.94 | 3 | 3.06 | V | |||
Measured at VCOUT,
VCn = 0 V |
0 | V | |||||
∆VCOUT | Cell voltage amplifier accuracy | VCn = 1.4 V to 4.4 V,
After correction, (2) Measured at VCOUT (3) REF_SEL = 1(4) |
TA = 25°C | –3 | 3 | mV | |
TA = 0°C to 50°C | –5 | 5 | |||||
TA = –25°C to +85°C | –8 | 8 | |||||
IVCOUT | VCOUT output current(5) | 10 | µA | ||||
tVCOUT | Delay from VCn select to VCOUT | Output step of 200 mV, COUT = 0.1 µF | 100 | µs |