SLUSAM9E July 2011 – April 2020
PRODUCTION DATA.
PARAMETER | TEST CONDITION | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
VPOR | Power on reset voltage | Measured at BAT pin | Initial BAT < 1.4 VBAT rising(1) | 4.3 | 4.5 | 4.7 | V |
Initial BAT > 1.4 VBAT rising(1) | 6.5 | 7 | 7.5 | V | |||
VSHUT | Shutdown voltage(2) | Measured at BAT pin, BAT falling | 3.6 | V | |||
tPOR | Time delay after POR before I2C comms allowed | CV3P3 = 4.7 µF | 1 | ms | |||
VWAKE | Wakeup voltage | Measured at ALERT pin | 0.8 | 2 | V | ||
tWAKE_PLS | Wakeup signal pulse width | 1 | 5 | μs | |||
tWAKE_DLY | Time delay after wakeup before I2C comms allowed | CV3P3 = 4.7 µF | 1 | ms |