SLUUBE0A November   2015  – August 2021 TPS549A20

 

  1.   Trademarks
  2. Introduction
  3. Description
    1. 2.1 Typical Applications
    2. 2.2 Features
  4. Electrical Performance Specifications
  5. Schematic
  6. Test Setup
    1. 5.1 Test Equipment
    2. 5.2 Recommended Test Setup
  7. Configurations
    1. 6.1 PMBus Address Selection
    2. 6.2 Mode Selection
    3. 6.3 VDD Pin Supply Selection
  8. Test Procedure
    1. 7.1 Line and Load Regulation and Efficiency Measurement Procedure
    2. 7.2 PMBUS Setup and Verification
    3. 7.3 Control-Loop Gain and Phase-Measurement Procedure
    4. 7.4 List of Test Points
    5. 7.5 Equipment Shutdown
  9. EVM Assembly Drawing and PCB Layout
  10. Bill of Materials
  11. 10Revision History

PMBus Address Selection

The PMBus address can be changed as shown in Table 6-1.

Table 6-1 PMBus Address Selection Settings
PMBus ADDRESSRESISTOR DIVIDER RATIO (Ω)(RHIGH) (kΩ)
HIGH-SIDE
RESISTOR
(RLOW) (kΩ)
LOW-SIDE
RESISTOR
(RLOW/RLOW+RHIGH)MINMAX
0011111
> 0.5571300
0011110
0.51000.49580.5247160165
0011101
0.4625044820.4772180154
0011100
0.41820.40730.4294200143
0011011
0.37720.36620.3886200120
0011010
0.33610.32490.3476220110
0011001
0.29850.29050.3067249105
0011000
0.26410.25600.272524988.7
0010111
0.22980.22150.238524071.5
0010110
0.19550.18700.204424960.4
0010101
0.16110.15240.170324947.5
0010100
0.12680.11790.136324936.0
0010011
0.09600.09000.102425527.0
0010010
0.06840.06220.075225518.7
0010001
0.04040.03400.048027011.5
0010000
< 0.0133001

For different switching frequency setting, please change R3 and R4 as shown in Table 6-1.