SLUUBG6 May 2017 BQ25700A , BQ25703A
This procedure details how to configure the PWR732 evaluation board. For the test procedure, the following naming conventions are followed. Refer to the PWR732 schematic for details.
VXXX: | External voltage supply name (VADP, VBT, VSBT) | |
LOADW: | External load name (LOADR, LOADI) | |
V(TPyyy): | Voltage at internal test point TPyyy. For example, V(TP12) means the voltage at TP12. | |
V(Jxx): | Voltage at jack terminal Jxx. | |
V(TP(XXX)): | Voltage at test point “XXX”. For example, V(ACDET) means the voltage at the test point which is marked as “ACDET”. | |
V(XXX, YYY): | Voltage across point XXX and YYY. | |
I(JXX(YYY)): | Current going out from the YYY terminal of jack XX. | |
Jxx(BBB): | Terminal or pin BBB of jack xx | |
Jxx ON : | Internal jumper Jxx terminals are shorted | |
Jxx OFF: | Internal jumper Jxx terminals are open | |
Jxx (-YY-) ON: | Internal jumper Jxx adjacent terminals marked as “YY” are shorted | |
Measure: → A,B | Check specified parameters A, B. If measured values are not within specified limits, the unit under test has failed. | |
Observe → A,B | Observe if A, B occurs. If they do not occur, the unit under test has failed. |
Assembly drawings have locations for jumpers, test points, and individual components.