2.4.2 OTG Function
Use the following for OTG function settings:
- Set EN_OTG high on J2 (EN_OTG) or short TP37 to TP35 (EN_OTG).
- Connect a 7-V power supply to the VBAT load. Remove the VIN power supply from J1. (Connection must be physically removed from board).
- Write the Charge Voltage Register to 0x20D0.
- Write “0200” to the OTG voltage register. Write “4000” to the OTG current registers.
- Select EN_OTG in Charge Option 3.
Measure → V(J1(VIN)) = 5 V ±1 V