Initial Settings

Use the following steps for enable the EVM test setup:

  1. Make sure Equipment Setup steps have been followed.
  2. Launch the BQ2561X EVM GUI software, if not already done.
  3. Turn on PS1:
    • Measure → Vsys (SYS-TP17 and PGND-TP30) = 4.20V ±0.3V
      Note:

      Completely dsconnect Load #1 from BATTERY connections if different value is seen.