SLUUCA6 October 2021 BQ27Z746
The device has a hardware-based overcurrent in discharge protection with adjustable current and delay time.
Status | Condition | Action |
---|---|---|
Normal | Current() > Protector OCD Threshold | SafetyStatus()[HOCD] = 0 |
Trip | Current() ≤ Protector OCD Threshold for Protector OCD Delay Time | SafetyStatus()[HOCD] = 1 OperationStatus()[XDSG] = 1 Turn off DSG FET |
Recovery | SafetyStatus()[HOCD] = 1 AND Current() ≥ HOCD:Recovery Thresholdfor HOCD:Recovery Delay time | SafetyStatus()[HOCD] = 0 OperationStatus()[XDSG] = 0 |