SLUUCA6 October 2021 BQ27Z746
The device can detect cell undervoltage in batteries and protect cells from damage by preventing further discharge.
Status | Condition | Action | ||
---|---|---|---|---|
Normal | Voltage() > CUV:Threshold | SafetyAlert()[CUV] = 0 BatteryStatus()[TDA] = 0 | ||
Alert | Voltage() ≤ CUV:Threshold | SafetyAlert()[CUV] = 1 BatteryStatus()[TDA] = 1 | ||
Trip | Voltage() ≤ CUV:Threshold for CUV:Delay duration | SafetyAlert()[CUV] = 0 SafetyStatus()[CUV] = 1 BatteryStatus()[FD] = 1, [TDA] = 0 OperationStatus()[XDSG] = 1 | ||
Recovery | Condition 1: SafetyStatus()[CUV] = 1 AND Voltage() ≥ CUV:Recovery for CUV:Recovery Delay AND Protection Configuration[CUV_RECOV_CHG] = 0 | SafetyStatus()[CUV] = 0 BatteryStatus()[FD] = 0, [TDA] = 0 OperationStatus()[XDSG] = 0 | ||
OR Condition 2: SafetyStatus()[CUV] = 1 AND Voltage() ≥ CUV:Recovery for CUV:Recovery Delay AND Protection Configuration[CUV_RECOV_CHG] = 1 AND Charging detected (that is, BatteryStatus()[DSG] = 0) |