SLUUCA6 October 2021 BQ27Z746
The device has five hardware-based protections—HCUV, HCOV, HOCC, HOCD, and HSCD—with adjustable threshold and delay time. The threshold settings are in mV; therefore, for current-based protections, the actual current that triggers the protection is based on the RSENSE used in the schematic design.
In general, when a fault is detected after the Delay time, the CHG and DSG FETs will be disabled (Trip stage). Since both FETs are off, the current will drop to 0 mA. After Recovery time, the CHG and DSG FETs will be turned on again (Recovery stage).