SLUUCD5 January 2023 BQ27427
Subclass | Subclass ID | Offset | Type | Name | Value | Unit | ||
---|---|---|---|---|---|---|---|---|
Min | Max | Default | ||||||
Discharge | 49 | 2 | U1 | SOCF Set Threshold | 0 | 100 | 2 | % |
3 | U1 | SOCF Clear Threshold | 0 | 100 | 5 | % |
When StateOfCharge() falls to or below the final capacity threshold, as specified in SOCF Set Threshold, the Flags() [SOCF] bit is set. This bit is cleared once StateOfCharge() rises to or above SOCF Clear Threshold. The [SOCF] bit serves as the final discharge warning.
These values are up to the user's preference.