SLUUCD5 January 2023 BQ27427
Subclass | Subclass ID | Offset | Type | Name | Value | Unit | ||
---|---|---|---|---|---|---|---|---|
Min | Max | Default | ||||||
State | 82 | 21 | I2 | Taper Rate | 0 | 2000 | 100 | 0.1 h rate |
29 | I2 | Taper Voltage | 0 | 5000 | 4100 | mV |
Taper Rate is used in the Primary Charge Termination Algorithm. AverageCurrent() is integrated over each of the two 40-second periods separately and averaged separately to determine two averages (IRateAvg1, IRateAvg2).
The Taper Voltage threshold defines the minimum voltage necessary as a qualifier for detection of charge termination.
Three requirements must be met to qualify for Primary Charge Termination:
When the Primary Charge Termination conditions are met, the Flags() [FC] bit is set and [CHG] bit is cleared. Also, if the OpConfig[RMFCC] bit is set, then RemainingCapacity() is set equal to FullChargeCapacity().