SLUUCG7 April   2024 BQ76922

 

  1.   1
  2.   Read This First
    1.     About This Manual
    2.     Battery Notational Conventions
    3.     Trademarks
    4.     Glossary
  3. Introduction
  4. Device Description
    1. 2.1 Overview
    2. 2.2 Functional Block Diagram
  5. Device Configuration
    1. 3.1 Direct Commands and Subcommands
    2. 3.2 Configuration Using OTP or Registers
    3. 3.3 Data Formats
      1. 3.3.1 Unsigned Integer
      2. 3.3.2 Integer
      3. 3.3.3 Floating Point
      4. 3.3.4 Hex
  6. Measurement Subsystem
    1. 4.1  Voltage Measurement
      1. 4.1.1 Voltage Measurement Schedule
      2. 4.1.2 Usage of VC Pins for Cells Versus Interconnect
      3. 4.1.3 Cell Interconnect Resistance
    2. 4.2  General Purpose ADCIN Functionality
    3. 4.3  Coulomb Counter and Digital Filters
    4. 4.4  Synchronized Voltage and Current Measurement
    5. 4.5  Subcommands 0x0071–0x0072 DASTATUS1-2() , Cell Voltage and Synchronized Current Counts
    6. 4.6  Subcommands 0x0075–0x0076 DASTATUS5-6(), Additional Measurements
    7. 4.7  Internal Temperature Measurement
    8. 4.8  Thermistor Temperature Measurement
    9. 4.9  Factory Trim of Voltage ADC
    10. 4.10 Voltage Calibration (ADC Measurements)
    11. 4.11 Voltage Calibration (COV and CUV Protections)
    12. 4.12 Current Calibration
    13. 4.13 Temperature Calibration
  7. Primary and Secondary Protection Subsystems
    1. 5.1 Protections Overview
    2. 5.2 Primary Protections
      1. 5.2.1  Primary Protections Overview
      2. 5.2.2  High-Side NFET Drivers
      3. 5.2.3  Protection FETs Configuration and Control
        1. 5.2.3.1 FET Configuration
        2. 5.2.3.2 FET Control
          1. 5.2.3.2.1 Precharge Mode
          2. 5.2.3.2.2 Predischarge Mode
      4. 5.2.4  Cell Overvoltage Protection
      5. 5.2.5  Cell Undervoltage Protection
      6. 5.2.6  Short Circuit in Discharge Protection
      7. 5.2.7  Overcurrent in Charge Protection
      8. 5.2.8  Overcurrent in Discharge 1, 2, and 3 Protections
      9. 5.2.9  Overtemperature in Charge Protection
      10. 5.2.10 Overtemperature in Discharge Protection
      11. 5.2.11 Overtemperature FET Protection
      12. 5.2.12 Internal Overtemperature Protection
      13. 5.2.13 Undertemperature in Charge Protection
      14. 5.2.14 Undertemperature in Discharge Protection
      15. 5.2.15 Internal Undertemperature Protection
      16. 5.2.16 Host Watchdog Protection
      17. 5.2.17 Precharge Timeout Protection
      18. 5.2.18 Load Detect Functionality
    3. 5.3 Secondary Protections
      1. 5.3.1  Secondary Protections Overview
      2. 5.3.2  Copper Deposition (CUDEP) Permanent Fail
      3. 5.3.3  Safety Undervoltage (SUV) Permanent Fail
      4. 5.3.4  Safety Overvoltage (SOV) Permanent Fail
      5. 5.3.5  Safety Overcurrent in Charge (SOCC) Permanent Fail
      6. 5.3.6  Safety Overcurrent in Discharge (SOCD) Permanent Fail
      7. 5.3.7  Safety Cell Overtemperature (SOT) Permanent Fail
      8. 5.3.8  Safety FET Overtemperature (SOTF) Permanent Fail
      9. 5.3.9  Charge FET (CFETF) Permanent Fail
      10. 5.3.10 Discharge FET (DFETF) Permanent Fail
      11. 5.3.11 Secondary Protector (2LVL) Permanent Fail
      12. 5.3.12 Voltage Imbalance in Relax (VIMR) Permanent Fail
      13. 5.3.13 Voltage Imbalance in Active (VIMA) Permanent Fail
      14. 5.3.14 Short Circuit in Discharge Latched Permanent Fail
      15. 5.3.15 OTP Memory Signature Permanent Fail
      16. 5.3.16 Data ROM Memory Signature Permanent Fail
      17. 5.3.17 Instruction ROM Memory Signature Permanent Fail
      18. 5.3.18 LFO Oscillator Permanent Fail
      19. 5.3.19 Voltage Reference Permanent Fail
      20. 5.3.20 VSS Permanent Fail
      21. 5.3.21 Protection Comparator MUX Permanent Fail
      22. 5.3.22 Commanded Permanent Fail
      23. 5.3.23 Top of Stack Measurement Check
      24. 5.3.24 Cell Open Wire
  8. Device Status and Controls
    1. 6.1 0x00 Control Status() and 0x12 Battery Status() Commands
    2. 6.2 0x0070 MANU_DATA() Subcommand
    3. 6.3 LDOs
      1. 6.3.1 Pre-Regulator Control
      2. 6.3.2 REG1 LDO Control
    4. 6.4 Multifunction Pin Controls
    5. 6.5 CFETOFF, DFETOFF, and BOTHOFF Pin Functionality
    6. 6.6 ALERT Pin Operation
    7. 6.7 Fuse Drive
    8. 6.8 Device Event Timing
  9. Operational Modes
    1. 7.1 Overview
    2. 7.2 NORMAL Mode
    3. 7.3 SLEEP Mode
    4. 7.4 DEEPSLEEP Mode
    5. 7.5 SHUTDOWN Mode
    6. 7.6 CONFIG_UPDATE Mode
  10. Device Security
    1. 8.1 Overview
  11. Serial Communications Interfaces
    1. 9.1 Serial Communications Overview
    2. 9.2 I2C Communications Subsystem
    3. 9.3 HDQ Communications Interface
  12. 10Cell Balancing
    1. 10.1 Cell Balancing Operation
    2. 10.2 Cell Balancing Timing
  13. 11Diagnostics
    1. 11.1 Diagnostics Overview
    2. 11.2 VREF2 Versus VREF1 Check
    3. 11.3 VSS Measurement
    4. 11.4 Top of Stack Measurement Check
    5. 11.5 LFO Oscillator Monitor
    6. 11.6 Protection Comparator Mux Check
    7. 11.7 Internal Watchdog Reset
    8. 11.8 Internal Memory Checks
  14. 12Commands and Subcommands
    1. 12.1 Direct Commands
    2. 12.2 Bitfield Definitions for Direct Commands
      1. 12.2.1  Control Status Register
      2. 12.2.2  Safety Alert A Register
      3. 12.2.3  Safety Status A Register
      4. 12.2.4  Safety Alert B Register
      5. 12.2.5  Safety Status B Register
      6. 12.2.6  Safety Alert C Register
      7. 12.2.7  Safety Status C Register
      8. 12.2.8  PF Alert A Register
      9. 12.2.9  PF Status A Register
      10. 12.2.10 PF Alert B Register
      11. 12.2.11 PF Status B Register
      12. 12.2.12 PF Alert C Register
      13. 12.2.13 PF Status C Register
      14. 12.2.14 PF Alert D Register
      15. 12.2.15 PF Status D Register
      16. 12.2.16 Battery Status Register
      17. 12.2.17 Alarm Status Register
      18. 12.2.18 Alarm Raw Status Register
      19. 12.2.19 Alarm Enable Register
      20. 12.2.20 FET Status Register
    3. 12.3 Command-Only Subcommands
    4. 12.4 Subcommands With Data
    5. 12.5 Bitfield Definitions for Subcommands
      1. 12.5.1 PF Status A Register
      2. 12.5.2 PF Status B Register
      3. 12.5.3 PF Status C Register
      4. 12.5.4 PF Status D Register
      5. 12.5.5 Manufacturing Status Register
      6. 12.5.6 FET Control Register
      7. 12.5.7 REG1 Control Register
      8. 12.5.8 OTP Write Check Result Register
      9. 12.5.9 OTP Write Result Register
  15. 13Data Memory Settings
    1. 13.1 Data Memory Access
    2. 13.2 Calibration
      1. 13.2.1  Calibration:Voltage
        1. 13.2.1.1 Calibration:Voltage:Cell 1 Gain
        2. 13.2.1.2 Calibration:Voltage:Cell 2 Gain
        3. 13.2.1.3 Calibration:Voltage:Cell 3 Gain
        4. 13.2.1.4 Calibration:Voltage:Cell 4 Gain
        5. 13.2.1.5 Calibration:Voltage:Cell 5 Gain
        6. 13.2.1.6 Calibration:Voltage:Pack Gain
        7. 13.2.1.7 Calibration:Voltage:TOS Gain
        8. 13.2.1.8 Calibration:Voltage:LD Gain
        9. 13.2.1.9 Calibration:Voltage:ADC Gain
      2. 13.2.2  Calibration:Current
        1. 13.2.2.1 Calibration:Current:CC Gain
        2. 13.2.2.2 Calibration:Current:Capacity Gain
      3. 13.2.3  Calibration:Vcell Offset
        1. 13.2.3.1 Calibration:Vcell Offset:Vcell Offset
      4. 13.2.4  Calibration:V Divider Offset
        1. 13.2.4.1 Calibration:V Divider Offset:Vdiv Offset
      5. 13.2.5  Calibration:Current Offset
        1. 13.2.5.1 Calibration:Current Offset:Coulomb Counter Offset Samples
        2. 13.2.5.2 Calibration:Current Offset:Board Offset
      6. 13.2.6  Calibration:Temperature
        1. 13.2.6.1 Calibration:Temperature:Internal Temp Offset
        2. 13.2.6.2 Calibration:Temperature:CFETOFF Temp Offset
        3. 13.2.6.3 Calibration:Temperature:DFETOFF Temp Offset
        4. 13.2.6.4 Calibration:Temperature:ALERT Temp Offset
        5. 13.2.6.5 Calibration:Temperature:TS1 Temp Offset
        6. 13.2.6.6 Calibration:Temperature:TS2 Temp Offset
      7. 13.2.7  Calibration:Internal Temp Model
        1. 13.2.7.1 Calibration:Internal Temp Model:Int Gain
        2. 13.2.7.2 Calibration:Internal Temp Model:Int base offset
        3. 13.2.7.3 Calibration:Internal Temp Model:Int Maximum AD
        4. 13.2.7.4 Calibration:Internal Temp Model:Int Maximum Temp
      8. 13.2.8  Calibration:18K Temperature Model
        1. 13.2.8.1  Calibration:18K Temperature Model:Coeff a1
        2. 13.2.8.2  Calibration:18K Temperature Model:Coeff a2
        3. 13.2.8.3  Calibration:18K Temperature Model:Coeff a3
        4. 13.2.8.4  Calibration:18K Temperature Model:Coeff a4
        5. 13.2.8.5  Calibration:18K Temperature Model:Coeff a5
        6. 13.2.8.6  Calibration:18K Temperature Model:Coeff b1
        7. 13.2.8.7  Calibration:18K Temperature Model:Coeff b2
        8. 13.2.8.8  Calibration:18K Temperature Model:Coeff b3
        9. 13.2.8.9  Calibration:18K Temperature Model:Coeff b4
        10. 13.2.8.10 Calibration:18K Temperature Model:Adc0
      9. 13.2.9  Calibration:180K Temperature Model
        1. 13.2.9.1  Calibration:180K Temperature Model:Coeff a1
        2. 13.2.9.2  Calibration:180K Temperature Model:Coeff a2
        3. 13.2.9.3  Calibration:180K Temperature Model:Coeff a3
        4. 13.2.9.4  Calibration:180K Temperature Model:Coeff a4
        5. 13.2.9.5  Calibration:180K Temperature Model:Coeff a5
        6. 13.2.9.6  Calibration:180K Temperature Model:Coeff b1
        7. 13.2.9.7  Calibration:180K Temperature Model:Coeff b2
        8. 13.2.9.8  Calibration:180K Temperature Model:Coeff b3
        9. 13.2.9.9  Calibration:180K Temperature Model:Coeff b4
        10. 13.2.9.10 Calibration:180K Temperature Model:Adc0
      10. 13.2.10 Calibration:Custom Temperature Model
        1. 13.2.10.1  Calibration:Custom Temperature Model:Coeff a1
        2. 13.2.10.2  Calibration:Custom Temperature Model:Coeff a2
        3. 13.2.10.3  Calibration:Custom Temperature Model:Coeff a3
        4. 13.2.10.4  Calibration:Custom Temperature Model:Coeff a4
        5. 13.2.10.5  Calibration:Custom Temperature Model:Coeff a5
        6. 13.2.10.6  Calibration:Custom Temperature Model:Coeff b1
        7. 13.2.10.7  Calibration:Custom Temperature Model:Coeff b2
        8. 13.2.10.8  Calibration:Custom Temperature Model:Coeff b3
        9. 13.2.10.9  Calibration:Custom Temperature Model:Coeff b4
        10. 13.2.10.10 Calibration:Custom Temperature Model:Rc0
        11. 13.2.10.11 Calibration:Custom Temperature Model:Adc0
      11. 13.2.11 Calibration:Current Deadband
        1. 13.2.11.1 Calibration:Current Deadband:Coulomb Counter Deadband
      12. 13.2.12 Calibration:CUV
        1. 13.2.12.1 Calibration:CUV:CUV Threshold Override
      13. 13.2.13 Calibration:COV
        1. 13.2.13.1 Calibration:COV:COV Threshold Override
    3. 13.3 Settings
      1. 13.3.1  Settings:Fuse
        1. 13.3.1.1 Settings:Fuse:Min Blow Fuse Voltage
        2. 13.3.1.2 Settings:Fuse:Fuse Blow Timeout
      2. 13.3.2  Settings:Configuration
        1. 13.3.2.1  Settings:Configuration:Power Config
        2. 13.3.2.2  Settings:Configuration:REG1 Config
        3. 13.3.2.3  Settings:Configuration:REG0 Config
        4. 13.3.2.4  Settings:Configuration:HWD Regulator Options
        5. 13.3.2.5  Settings:Configuration:Comm Type
        6. 13.3.2.6  Settings:Configuration:I2C Address
        7. 13.3.2.7  Settings:Configuration:Comm Idle Time
        8. 13.3.2.8  Settings:Configuration:CFETOFF Pin Config
        9. 13.3.2.9  Settings:Configuration:DFETOFF Pin Config
        10. 13.3.2.10 Settings:Configuration:ALERT Pin Config
        11. 13.3.2.11 Settings:Configuration:TS1 Config
        12. 13.3.2.12 Settings:Configuration:TS2 Config
        13. 13.3.2.13 Settings:Configuration:DA Configuration
        14. 13.3.2.14 Settings:Configuration:Vcell Mode
        15. 13.3.2.15 Settings:Configuration:CC3 Samples
      3. 13.3.3  Settings:Protection
        1. 13.3.3.1  Settings:Protection:Protection Configuration
        2. 13.3.3.2  Settings:Protection:Enabled Protections A
        3. 13.3.3.3  Settings:Protection:Enabled Protections B
        4. 13.3.3.4  Settings:Protection:Enabled Protections C
        5. 13.3.3.5  Settings:Protection:CHG FET Protections A
        6. 13.3.3.6  Settings:Protection:CHG FET Protections B
        7. 13.3.3.7  Settings:Protection:CHG FET Protections C
        8. 13.3.3.8  Settings:Protection:DSG FET Protections A
        9. 13.3.3.9  Settings:Protection:DSG FET Protections B
        10. 13.3.3.10 Settings:Protection:DSG FET Protections C
        11. 13.3.3.11 Settings:Protection:Body Diode Threshold
      4. 13.3.4  Settings:Alarm
        1. 13.3.4.1 Settings:Alarm:Default Alarm Mask
        2. 13.3.4.2 Settings:Alarm:SF Alert Mask A
        3. 13.3.4.3 Settings:Alarm:SF Alert Mask B
        4. 13.3.4.4 Settings:Alarm:SF Alert Mask C
        5. 13.3.4.5 Settings:Alarm:PF Alert Mask A
        6. 13.3.4.6 Settings:Alarm:PF Alert Mask B
        7. 13.3.4.7 Settings:Alarm:PF Alert Mask C
        8. 13.3.4.8 Settings:Alarm:PF Alert Mask D
      5. 13.3.5  Settings:Permanent Failure
        1. 13.3.5.1 Settings:Permanent Failure:Enabled PF A
        2. 13.3.5.2 Settings:Permanent Failure:Enabled PF B
        3. 13.3.5.3 Settings:Permanent Failure:Enabled PF C
        4. 13.3.5.4 Settings:Permanent Failure:Enabled PF D
      6. 13.3.6  Settings:FET
        1. 13.3.6.1 Settings:FET:FET Options
        2. 13.3.6.2 Settings:FET:Chg Pump Control
        3. 13.3.6.3 Settings:FET:Precharge Start Voltage
        4. 13.3.6.4 Settings:FET:Precharge Stop Voltage
        5. 13.3.6.5 Settings:FET:Predischarge Timeout
        6. 13.3.6.6 Settings:FET:Predischarge Stop Delta
      7. 13.3.7  Settings:Current Thresholds
        1. 13.3.7.1 Settings:Current Thresholds:Dsg Current Threshold
        2. 13.3.7.2 Settings:Current Thresholds:Chg Current Threshold
      8. 13.3.8  Settings:Cell Open-Wire
        1. 13.3.8.1 Settings:Cell Open-Wire:Check Time
      9. 13.3.9  Settings:Interconnect Resistances
        1. 13.3.9.1 Settings:Interconnect Resistances:Cell 1 Interconnect
        2. 13.3.9.2 Settings:Interconnect Resistances:Cell 2 Interconnect
        3. 13.3.9.3 Settings:Interconnect Resistances:Cell 3 Interconnect
        4. 13.3.9.4 Settings:Interconnect Resistances:Cell 4 Interconnect
        5. 13.3.9.5 Settings:Interconnect Resistances:Cell 5 Interconnect
      10. 13.3.10 Settings:Manufacturing
        1. 13.3.10.1 Settings:Manufacturing:Mfg Status Init
      11. 13.3.11 Settings:Cell Balancing Config
        1. 13.3.11.1  Settings:Cell Balancing Config:Balancing Configuration
        2. 13.3.11.2  Settings:Cell Balancing Config:Min Cell Temp
        3. 13.3.11.3  Settings:Cell Balancing Config:Max Cell Temp
        4. 13.3.11.4  Settings:Cell Balancing Config:Max Internal Temp
        5. 13.3.11.5  Settings:Cell Balancing Config:Cell Balance Interval
        6. 13.3.11.6  Settings:Cell Balancing Config:Cell Balance Max Cells
        7. 13.3.11.7  Settings:Cell Balancing Config:Cell Balance Min Cell V (Charge)
        8. 13.3.11.8  Settings:Cell Balancing Config:Cell Balance Min Delta (Charge)
        9. 13.3.11.9  Settings:Cell Balancing Config:Cell Balance Stop Delta (Charge)
        10. 13.3.11.10 Settings:Cell Balancing Config:Cell Balance Min Cell V (Relax)
        11. 13.3.11.11 Settings:Cell Balancing Config:Cell Balance Min Delta (Relax)
        12. 13.3.11.12 Settings:Cell Balancing Config:Cell Balance Stop Delta (Relax)
    4. 13.4 Power
      1. 13.4.1 Power:Shutdown
        1. 13.4.1.1 Power:Shutdown:Shutdown Cell Voltage
        2. 13.4.1.2 Power:Shutdown:Shutdown Stack Voltage
        3. 13.4.1.3 Power:Shutdown:Low V Shutdown Delay
        4. 13.4.1.4 Power:Shutdown:Shutdown Temperature
        5. 13.4.1.5 Power:Shutdown:Shutdown Temperature Delay
        6. 13.4.1.6 Power:Shutdown:FET Off Delay
        7. 13.4.1.7 Power:Shutdown:Shutdown Command Delay
        8. 13.4.1.8 Power:Shutdown:Auto Shutdown Time
        9. 13.4.1.9 Power:Shutdown:RAM Fail Shutdown Time
      2. 13.4.2 Power:Sleep
        1. 13.4.2.1 Power:Sleep:Sleep Current
        2. 13.4.2.2 Power:Sleep:Voltage Time
        3. 13.4.2.3 Power:Sleep:Wake Comparator Current
        4. 13.4.2.4 Power:Sleep:Sleep Hysteresis Time
        5. 13.4.2.5 Power:Sleep:Sleep Charger Voltage Threshold
        6. 13.4.2.6 Power:Sleep:Sleep Charger PACK-TOS Delta
    5. 13.5 System Data
      1. 13.5.1 System Data:Integrity
        1. 13.5.1.1 System Data:Integrity:Config RAM Signature
    6. 13.6 Protections
      1. 13.6.1  Protections:CUV
        1. 13.6.1.1 Protections:CUV:Threshold
        2. 13.6.1.2 Protections:CUV:Delay
        3. 13.6.1.3 Protections:CUV:Recovery Hysteresis
      2. 13.6.2  Protections:COV
        1. 13.6.2.1 Protections:COV:Threshold
        2. 13.6.2.2 Protections:COV:Delay
        3. 13.6.2.3 Protections:COV:Recovery Hysteresis
      3. 13.6.3  Protections:COVL
        1. 13.6.3.1 Protections:COVL:Latch Limit
        2. 13.6.3.2 Protections:COVL:Counter Dec Delay
        3. 13.6.3.3 Protections:COVL:Recovery Time
      4. 13.6.4  Protections:OCC
        1. 13.6.4.1 Protections:OCC:Threshold
        2. 13.6.4.2 Protections:OCC:Delay
        3. 13.6.4.3 Protections:OCC:Recovery Threshold
        4. 13.6.4.4 Protections:OCC:PACK-TOS Delta
      5. 13.6.5  Protections:OCD1
        1. 13.6.5.1 Protections:OCD1:Threshold
        2. 13.6.5.2 Protections:OCD1:Delay
      6. 13.6.6  Protections:OCD2
        1. 13.6.6.1 Protections:OCD2:Threshold
        2. 13.6.6.2 Protections:OCD2:Delay
      7. 13.6.7  Protections:SCD
        1. 13.6.7.1 Protections:SCD:Threshold
        2. 13.6.7.2 Protections:SCD:Delay
        3. 13.6.7.3 Protections:SCD:Recovery Time
      8. 13.6.8  Protections:OCD3
        1. 13.6.8.1 Protections:OCD3:Threshold
        2. 13.6.8.2 Protections:OCD3:Delay
      9. 13.6.9  Protections:OCD
        1. 13.6.9.1 Protections:OCD:Recovery Threshold
      10. 13.6.10 Protections:OCDL
        1. 13.6.10.1 Protections:OCDL:Latch Limit
        2. 13.6.10.2 Protections:OCDL:Counter Dec Delay
        3. 13.6.10.3 Protections:OCDL:Recovery Time
        4. 13.6.10.4 Protections:OCDL:Recovery Threshold
      11. 13.6.11 Protections:SCDL
        1. 13.6.11.1 Protections:SCDL:Latch Limit
        2. 13.6.11.2 Protections:SCDL:Counter Dec Delay
        3. 13.6.11.3 Protections:SCDL:Recovery Time
        4. 13.6.11.4 Protections:SCDL:Recovery Threshold
      12. 13.6.12 Protections:OTC
        1. 13.6.12.1 Protections:OTC:Threshold
        2. 13.6.12.2 Protections:OTC:Delay
        3. 13.6.12.3 Protections:OTC:Recovery
      13. 13.6.13 Protections:OTD
        1. 13.6.13.1 Protections:OTD:Threshold
        2. 13.6.13.2 Protections:OTD:Delay
        3. 13.6.13.3 Protections:OTD:Recovery
      14. 13.6.14 Protections:OTF
        1. 13.6.14.1 Protections:OTF:Threshold
        2. 13.6.14.2 Protections:OTF:Delay
        3. 13.6.14.3 Protections:OTF:Recovery
      15. 13.6.15 Protections:OTINT
        1. 13.6.15.1 Protections:OTINT:Threshold
        2. 13.6.15.2 Protections:OTINT:Delay
        3. 13.6.15.3 Protections:OTINT:Recovery
      16. 13.6.16 Protections:UTC
        1. 13.6.16.1 Protections:UTC:Threshold
        2. 13.6.16.2 Protections:UTC:Delay
        3. 13.6.16.3 Protections:UTC:Recovery
      17. 13.6.17 Protections:UTD
        1. 13.6.17.1 Protections:UTD:Threshold
        2. 13.6.17.2 Protections:UTD:Delay
        3. 13.6.17.3 Protections:UTD:Recovery
      18. 13.6.18 Protections:UTINT
        1. 13.6.18.1 Protections:UTINT:Threshold
        2. 13.6.18.2 Protections:UTINT:Delay
        3. 13.6.18.3 Protections:UTINT:Recovery
      19. 13.6.19 Protections:Recovery
        1. 13.6.19.1 Protections:Recovery:Time
      20. 13.6.20 Protections:HWD
        1. 13.6.20.1 Protections:HWD:Delay
      21. 13.6.21 Protections:Load Detect
        1. 13.6.21.1 Protections:Load Detect:Active Time
        2. 13.6.21.2 Protections:Load Detect:Retry Delay
        3. 13.6.21.3 Protections:Load Detect:Timeout
      22. 13.6.22 Protections:PTO
        1. 13.6.22.1 Protections:PTO:Charge Threshold
        2. 13.6.22.2 Protections:PTO:Delay
        3. 13.6.22.3 Protections:PTO:Reset
    7. 13.7 Permanent Fail
      1. 13.7.1  Permanent Fail:CUDEP
        1. 13.7.1.1 Permanent Fail:CUDEP:Threshold
        2. 13.7.1.2 Permanent Fail:CUDEP:Delay
      2. 13.7.2  Permanent Fail:SUV
        1. 13.7.2.1 Permanent Fail:SUV:Threshold
        2. 13.7.2.2 Permanent Fail:SUV:Delay
      3. 13.7.3  Permanent Fail:SOV
        1. 13.7.3.1 Permanent Fail:SOV:Threshold
        2. 13.7.3.2 Permanent Fail:SOV:Delay
      4. 13.7.4  Permanent Fail:TOS
        1. 13.7.4.1 Permanent Fail:TOS:Threshold
        2. 13.7.4.2 Permanent Fail:TOS:Delay
      5. 13.7.5  Permanent Fail:SOCC
        1. 13.7.5.1 Permanent Fail:SOCC:Threshold
        2. 13.7.5.2 Permanent Fail:SOCC:Delay
      6. 13.7.6  Permanent Fail:SOCD
        1. 13.7.6.1 Permanent Fail:SOCD:Threshold
        2. 13.7.6.2 Permanent Fail:SOCD:Delay
      7. 13.7.7  Permanent Fail:SOT
        1. 13.7.7.1 Permanent Fail:SOT:Threshold
        2. 13.7.7.2 Permanent Fail:SOT:Delay
      8. 13.7.8  Permanent Fail:SOTF
        1. 13.7.8.1 Permanent Fail:SOTF:Threshold
        2. 13.7.8.2 Permanent Fail:SOTF:Delay
      9. 13.7.9  Permanent Fail:VIMR
        1. 13.7.9.1 Permanent Fail:VIMR:Check Voltage
        2. 13.7.9.2 Permanent Fail:VIMR:Max Relax Current
        3. 13.7.9.3 Permanent Fail:VIMR:Threshold
        4. 13.7.9.4 Permanent Fail:VIMR:Delay
        5. 13.7.9.5 Permanent Fail:VIMR:Relax Min Duration
      10. 13.7.10 Permanent Fail:VIMA
        1. 13.7.10.1 Permanent Fail:VIMA:Check Voltage
        2. 13.7.10.2 Permanent Fail:VIMA:Min Active Current
        3. 13.7.10.3 Permanent Fail:VIMA:Threshold
        4. 13.7.10.4 Permanent Fail:VIMA:Delay
      11. 13.7.11 Permanent Fail:CFETF
        1. 13.7.11.1 Permanent Fail:CFETF:OFF Threshold
        2. 13.7.11.2 Permanent Fail:CFETF:OFF Delay
      12. 13.7.12 Permanent Fail:DFETF
        1. 13.7.12.1 Permanent Fail:DFETF:OFF Threshold
        2. 13.7.12.2 Permanent Fail:DFETF:OFF Delay
      13. 13.7.13 Permanent Fail:VSSF
        1. 13.7.13.1 Permanent Fail:VSSF:Fail Threshold
        2. 13.7.13.2 Permanent Fail:VSSF:Delay
      14. 13.7.14 Permanent Fail:2LVL
        1. 13.7.14.1 Permanent Fail:2LVL:Delay
      15. 13.7.15 Permanent Fail:LFOF
        1. 13.7.15.1 Permanent Fail:LFOF:Delay
      16. 13.7.16 Permanent Fail:HWMX
        1. 13.7.16.1 Permanent Fail:HWMX:Delay
    8. 13.8 Security
      1. 13.8.1 Security:Settings
        1. 13.8.1.1 Security:Settings:Security Settings
      2. 13.8.2 Security:Keys
        1. 13.8.2.1 Security:Keys:Unseal Key Step 1
        2. 13.8.2.2 Security:Keys:Unseal Key Step 2
        3. 13.8.2.3 Security:Keys:Full Access Key Step 1
        4. 13.8.2.4 Security:Keys:Full Access Key Step 2
    9. 13.9 Data Memory Summary
  16. 14Revision History

0x00 Control Status() and 0x12 Battery Status() Commands

The BQ76922 device includes 0x00 Control Status() and 0x12 Battery Status() commands, which report various status information on the pack. The 0x00 Control Status() command behaves similarly to 0x3E and 0x3F when written, this functionality is included for legacy auto-detection and is not recommended for customer usage. When this command is read back immediately after it has been written, it will return 0xFFA5 once. Subsequent reads will return the 0x00 Control Status() data, which is described below with the 0x12 Battery Status() details.

Table 6-1 0x00 Control Status() Bit Definitions
BitNameDescription
15 - 3RSVDReserved
2DEEPSLEEPThis bit indicates whether or not the device is in DEEPSLEEP mode.
DEEPSLEEP = 0: Device is not in DEEPSLEEP mode.
DEEPSLEEP = 1: Device is in DEEPSLEEP mode.
1LD_TIMEOUTThis bit is set when the Load Detect function has timed out and checking has stopped.
LD_TIMEOUT = 0: Load Detect function has not timed out or is inactive.
LD_TIMEOUT = 1: Load Detection function timed out and was deactivated.
0LD_ONThis bit indicates whether or not the Load Detect pullup was active during the previous LD pin voltage measurement.
LD_ON = 0: LD pullup was not active during the previous LD pin measurement.
LD_ON = 1: LD pullup was active during the previous LD pin measurement.
Table 6-2 0x12 Battery Status() Bit Definitions
BitNameDescription
15SLEEPThis bit indicates whether or not the device is presently in SLEEP mode.
SLEEP = 0: Device is not in SLEEP mode.
SLEEP = 1: Device is in SLEEP mode.
14RSVDReserved
13SDMSHUTDOWN mode is pending because the Shutdown() subcommand was received, or the RST_SHUT pin was asserted for > 1-sec.
SDM = 0: Shutdown due to command or pin is not pending.
SDM = 1: Shutdown due to command or pin is pending.
12PFIndicates whether a Permanent Fail fault has triggered.
PF = 0: No Permanent Fail fault has triggered.
PF = 1: At least one Permanent Fail fault has triggered.
11SSIndicates whether an enabled safety fault has triggered
SS = 0: No safety fault is triggered.
SS = 1: At least one enabled safety fault is triggered.
10FUSEReports the most recently observed state of the FUSE pin, is updated every second in NORMAL mode.
FUSE = 0: FUSE pin was not asserted by device or secondary protector at last sample.
FUSE = 1: FUSE pin was asserted by device or secondary protector at last sample.
9SEC1SEC1:0 indicate the present security state of the device.
SEC1:0 = 0: Device has not initialized yet.
SEC1:0 = 1: Device is in FULLACCESS mode.
SEC1:0 = 2: Device is in UNSEALED mode.
SEC1:0 = 3: Device is in SEALED mode.
When in SEALED mode, device configuration may not be read or written and some commands are restricted.
When in UNSEALED mode, device configuration may normally be read and may be written while in CONFIG_UPDATE mode.
When in FULLACCESS mode, unrestricted read and write access is allowed and all commands are accepted.
8SEC0
7OTPBThis bit indicates whether or not voltage and temperature conditions are valid for OTP programming. During normal operation, this bit will always be set if Manufacturing Status()[OTPW] is clear. When entering CONFIG_UPDATE mode, conditions will be checked and this bit will reflect whether or not programming is allowed (Manufacturing Status()[OTPW] does not apply in CONFIG_UPDATE mode). Once in CONFIG_UPDATE mode, this bit will not change state since no new measurements are being taken.
OTPB = 0: OTP writes are allowed.
OTPB = 1: Writes to OTP are blocked.
6OTPWThis bit indicates whether or not some data is waiting to be written to OTP during normal operation. This can occur when, for example, configured to Permanent Fail information to OTP. This bit may remain set until conditions for OTP programming are met and all data is programmed. This bit is not set during OTP programming from CONFIG_UPDATE mode.
OTPW = 0: No writes to OTP are pending.
OTPW = 1: Writes to OTP are pending.
5COW_CHKThis bit indicates while cell open-wire checks are occurring. When the feature is disabled, this bit will not set. When the feature is enabled, this bit will set periodically as the checks are performed.
COW_CHK = 0: Device is not actively performing a cell open-wire check.
COW_CHK = 1: Device is actively performing a cell open-wire check.
4WDThis bit indicates whether or not the previous device reset was caused by the internal watchdog timer. This is not related to the Host Watchdog protection.
WD = 0: Previous reset was normal.
WD = 1: Previous reset was caused by the watchdog timer.
3PORThis bit is set when the device fully resets. It is cleared upon exit of CONFIG_UPDATE mode. It can be used by the host to determine if any RAM configuration changes were lost due to a reset.
POR = 0: Full reset has not occurred since last exit of CONFIG_UPDATE mode.
POR = 1: Full reset has occurred since last exit of CONFIG_UPDATE and reconfiguration of any RAM settings is required.
2SLEEP_ENThis bit indicates whether or not SLEEP mode is allowed based on configuration and commands. The Settings:Configuration:Power Config[SLEEP_EN] bit sets the default state of this bit. The host may send commands to enable or disable SLEEP mode based on system requirements. When this bit is set, the device may transition to SLEEP mode when other SLEEP criteria are met.
SLEEP_EN = 0: SLEEP mode is disabled by the host.
SLEEP_EN = 1: SLEEP mode is allowed when other SLEEP conditions are met.
1PCHG_MODEThis bit indicates whether or not the device is in PRECHARGE mode. In PRECHARGE mode, the PCHG FET is turned on instead of the CHG FET.
PCHG_MODE = 0: Device is not in PRECHARGE mode.
PCHG_MODE = 1: Device is in PRECHARGE mode.
0CFGUPDATEThis bit indicates whether or not the device is in CONFIG_UPDATE mode. It will be set after the 0x0090 SET_CFGUPDATE() subcommand is received and fully processed. Configuration settings may be changed only while this bit is set.
CFGUPDATE = 0: Device is not in CONFIG_UPDATE mode.
CFGUPDATE = 1: Device is in CONFIG_UPDATE mode.