SLUUCI8 November   2023 BQ76905

 

  1.   1
  2.   Read This First
    1.     About This Manual
    2.     Battery Notational Conventions
    3.     Trademarks
    4.     Glossary
  3. Introduction
  4. Device Description
    1. 2.1 Overview
    2. 2.2 Functional Block Diagram
  5. Device Configuration
    1. 3.1 Direct Commands and Subcommands
    2. 3.2 Configuration Using OTP or Registers
    3. 3.3 Data Formats
      1. 3.3.1 Unsigned Integer
      2. 3.3.2 Integer
      3. 3.3.3 Hex
  6. Device Security
  7. Measurement Subsystem
    1. 5.1 Voltage Measurement
      1. 5.1.1 Voltage Measurement Schedule
      2. 5.1.2 Unused VC Cell Input Pins
      3. 5.1.3 General Purpose ADCIN Functionality
    2. 5.2 Coulomb Counter and Digital Filters
    3. 5.3 Internal Temperature Measurement
    4. 5.4 Thermistor Temperature Measurement
    5. 5.5 Measurement Calibration
  8. Protection Subsystem
    1. 6.1  Protections Overview
    2. 6.2  Protection FET Drivers
    3. 6.3  Cell Overvoltage Protection
    4. 6.4  Cell Undervoltage Protection
    5. 6.5  Short Circuit in Discharge Protection
    6. 6.6  Overcurrent in Charge Protection
    7. 6.7  Overcurrent in Discharge 1 and 2 Protections
    8. 6.8  Current Protection Latch
    9. 6.9  CHG Detector
    10. 6.10 Overtemperature in Charge Protection
    11. 6.11 Overtemperature in Discharge Protection
    12. 6.12 Internal Overtemperature Protection
    13. 6.13 Undertemperature in Charge Protection
    14. 6.14 Undertemperature in Discharge Protection
    15. 6.15 Host Watchdog Protection
    16. 6.16 Cell Open Wire Detection
    17. 6.17 Voltage Reference Measurement Diagnostic Protection
    18. 6.18 VSS Measurement Diagnostic Protection
    19. 6.19 REGOUT Diagnostic Protection
    20. 6.20 LFO Oscillator Integrity Diagnostic Protection
    21. 6.21 Internal Factory Trim Diagnostic Protection
  9. Device Status and Controls
    1. 7.1 0x00 Control Status() and 0x12 Battery Status() Commands
    2. 7.2 LDOs
    3. 7.3 ALERT Pin Operation
    4. 7.4 TS Pin Operation
    5. 7.5 Programmable Timer
    6. 7.6 Device Event Timing
  10. Operational Modes
    1. 8.1 Overview of Operational Modes
    2. 8.2 NORMAL Mode
    3. 8.3 SLEEP Mode
    4. 8.4 DEEPSLEEP Mode
    5. 8.5 SHUTDOWN Mode
    6. 8.6 CONFIG_UPDATE Mode
  11. I2C Serial Communications
    1. 9.1 I2C Serial Communications Interface
  12. 10Cell Balancing
    1. 10.1 Cell Balancing
  13. 11Commands and Subcommands
    1. 11.1 Direct Commands
    2. 11.2 Bit field Definitions for Direct Commands
      1. 11.2.1  Safety Alert A Register
      2. 11.2.2  Safety Status A Register
      3. 11.2.3  Safety Alert B Register
      4. 11.2.4  Safety Status B Register
      5. 11.2.5  Battery Status Register
      6. 11.2.6  Alarm Status Register
      7. 11.2.7  Alarm Raw Status Register
      8. 11.2.8  Alarm Enable Register
      9. 11.2.9  FET CONTROL Register
      10. 11.2.10 REGOUT CONTROL Register
      11. 11.2.11 DSG FET Driver PWM Control Register
      12. 11.2.12 CHG FET Driver PWM Control Register
    3. 11.3 Command-only Subcommands
    4. 11.4 Subcommands with Data
    5. 11.5 Bit field Definitions for Subcommands
      1. 11.5.1 DEVICE NUMBER Register
      2. 11.5.2 FW VERSION Register
      3. 11.5.3 HW VERSION Register
      4. 11.5.4 SECURITY KEYS Register
      5. 11.5.5 CB ACTIVE CELLS Register
      6. 11.5.6 PROG TIMER Register
      7. 11.5.7 PROT RECOVERY Register
  14. 12Data Memory
    1. 12.1 Calibration
      1. 12.1.1 Calibration:Voltage
        1. 12.1.1.1 Calibration:Voltage:Cell 1 Gain
        2. 12.1.1.2 Calibration:Voltage:Cell 2 Gain Delta
        3. 12.1.1.3 Calibration:Voltage:Cell 3 Gain Delta
        4. 12.1.1.4 Calibration:Voltage:Cell 4 Gain Delta
        5. 12.1.1.5 Calibration:Voltage:Cell 5 Gain Delta
        6. 12.1.1.6 Calibration:Voltage:Stack Gain
      2. 12.1.2 Calibration:Current
        1. 12.1.2.1 Calibration:Current:Curr Gain
        2. 12.1.2.2 Calibration:Current:Curr Offset
        3. 12.1.2.3 Calibration:Current:CC1 Gain
        4. 12.1.2.4 Calibration:Current:CC1 Offset
      3. 12.1.3 Calibration:Temperature
        1. 12.1.3.1 Calibration:Temperature:TS Offset
        2. 12.1.3.2 Calibration:Temperature:Int Temp Gain
        3. 12.1.3.3 Calibration:Temperature:Int Temp Offset
    2. 12.2 Settings
      1. 12.2.1 Settings:Configuration
        1. 12.2.1.1 Settings:Configuration:Power Config
        2. 12.2.1.2 Settings:Configuration:REGOUT Config
        3. 12.2.1.3 Settings:Configuration:I2C Address
        4. 12.2.1.4 Settings:Configuration:I2C Config
        5. 12.2.1.5 Settings:Configuration:DA Config
        6. 12.2.1.6 Settings:Configuration:Vcell Mode
        7. 12.2.1.7 Settings:Configuration:Default Alarm Mask
        8. 12.2.1.8 Settings:Configuration:FET Options
        9. 12.2.1.9 Settings:Configuration:Charge Detector Time
      2. 12.2.2 Settings:Cell Balancing
        1. 12.2.2.1 Settings:Cell Balancing:Balancing Configuration
        2. 12.2.2.2 Settings:Cell Balancing:Min Temp Threshold
        3. 12.2.2.3 Settings:Cell Balancing:Max Temp Threshold
        4. 12.2.2.4 Settings:Cell Balancing:Max Internal Temp
      3. 12.2.3 Settings:Protection
        1. 12.2.3.1 Settings:Protection:Enabled Protections A
        2. 12.2.3.2 Settings:Protection:Enabled Protections B
        3. 12.2.3.3 Settings:Protection:DSG FET Protections A
        4. 12.2.3.4 Settings:Protection:CHG FET Protections A
        5. 12.2.3.5 Settings:Protection:Both FET Protections B
        6. 12.2.3.6 Settings:Protection:Body Diode Threshold
        7. 12.2.3.7 Settings:Protection:Cell Open Wire NORMAL Check Time
        8. 12.2.3.8 Settings:Protection:Cell Open Wire SLEEP Check Time
        9. 12.2.3.9 Settings:Protection:Host Watchdog Timeout
    3. 12.3 Protections
      1. 12.3.1 Protections:Cell Voltage
        1. 12.3.1.1 Protections:Cell Voltage:Cell Undervoltage Protection Threshold
        2. 12.3.1.2 Protections:Cell Voltage:Cell Undervoltage Protection Delay
        3. 12.3.1.3 Protections:Cell Voltage:Cell Undervoltage Protection Recovery Hysteresis
        4. 12.3.1.4 Protections:Cell Voltage:Cell Overvoltage Protection Threshold
        5. 12.3.1.5 Protections:Cell Voltage:Cell Overvoltage Protection Delay
        6. 12.3.1.6 Protections:Cell Voltage:Cell Overvoltage Protection Recovery Hysteresis
      2. 12.3.2 Protections:Current
        1. 12.3.2.1  Protections:Current:Overcurrent in Charge Protection Threshold
        2. 12.3.2.2  Protections:Current:Overcurrent in Charge Protection Delay
        3. 12.3.2.3  Protections:Current:Overcurrent in Discharge 1 Protection Threshold
        4. 12.3.2.4  Protections:Current:Overcurrent in Discharge 1 Protection Delay
        5. 12.3.2.5  Protections:Current:Overcurrent in Discharge 2 Protection Threshold
        6. 12.3.2.6  Protections:Current:Overcurrent in Discharge 2 Protection Delay
        7. 12.3.2.7  Protections:Current:Short Circuit in Discharge Protection Threshold
        8. 12.3.2.8  Protections:Current:Short Circuit in Discharge Protection Delay
        9. 12.3.2.9  Protections:Current:Latch Limit
        10. 12.3.2.10 Protections:Current:Recovery Time
      3. 12.3.3 Protections:Temperature
        1. 12.3.3.1  Protections:Temperature:Overtemperature in Charge Protection Threshold
        2. 12.3.3.2  Protections:Temperature:Overtemperature in Charge Protection Delay
        3. 12.3.3.3  Protections:Temperature:Overtemperature in Charge Protection Recovery
        4. 12.3.3.4  Protections:Temperature:Undertemperature in Charge Protection Threshold
        5. 12.3.3.5  Protections:Temperature:Undertemperature in Charge Protection Delay
        6. 12.3.3.6  Protections:Temperature:Undertemperature in Charge Protection Recovery
        7. 12.3.3.7  Protections:Temperature:Overtemperature in Discharge Protection Threshold
        8. 12.3.3.8  Protections:Temperature:Overtemperature in Discharge Protection Delay
        9. 12.3.3.9  Protections:Temperature:Overtemperature in Discharge Protection Recovery
        10. 12.3.3.10 Protections:Temperature:Undertemperature in Discharge Protection Threshold
        11. 12.3.3.11 Protections:Temperature:Undertemperature in Discharge Protection Delay
        12. 12.3.3.12 Protections:Temperature:Undertemperature in Discharge Protection Recovery
        13. 12.3.3.13 Protections:Temperature:Internal Overtemperature Protection Threshold
        14. 12.3.3.14 Protections:Temperature:Internal Overtemperature Protection Delay
        15. 12.3.3.15 Protections:Temperature:Internal Overtemperature Protection Recovery
    4. 12.4 Power
      1. 12.4.1 Power:Sleep
        1. 12.4.1.1 Power:Sleep:Sleep Current
        2. 12.4.1.2 Power:Sleep:Voltage Time
        3. 12.4.1.3 Power:Sleep:Wake Comparator Current
      2. 12.4.2 Power:Shutdown
        1. 12.4.2.1 Power:Shutdown:Shutdown Cell Voltage
        2. 12.4.2.2 Power:Shutdown:Shutdown Stack Voltage
        3. 12.4.2.3 Power:Shutdown:Shutdown Temperature
        4. 12.4.2.4 Power:Shutdown:Auto Shutdown Time
    5. 12.5 Security
      1. 12.5.1 Security:Settings
        1. 12.5.1.1 Security:Settings:Security Settings
        2. 12.5.1.2 Security:Settings:Full Access Key Step 1
        3. 12.5.1.3 Security:Settings:Full Access Key Step 2
    6. 12.6 Data Memory Summary
  15. 13Revision History

0x00 Control Status() and 0x12 Battery Status() Commands

The BQ76905 device includes a 0x00 Control Status() command, which is primarily intended for legacy bqStudio auto-detection and is not recommended for customer usage. The 0x00 Control Status() command behaves similarly to 0x3E and 0x3F when written, accepting subcommand addresses. When this command is read back immediately after it has been written, it returns 0xFFA5 once.

The device also includes the 0x12 Battery Status() command, which reports various status information on the pack, as shown below.

Table 7-1 0x12 Battery Status() Bit Definitions
Bit Name Description
15 SLEEP This flag asserts if the device is in SLEEP mode

0x0 = Device is not in SLEEP mode

0x1 = Device is in SLEEP mode
14 DEEPSLEEP This flag asserts if the device is in DEEPSLEEP mode

0x0 = Device is not in DEEPSLEEP mode

0x1 = Device is in DEEPSLEEP mode
13 SA This flag asserts if an enabled safety alert is present.

0x0 = Indicates an enabled safety alert is not present

0x1 = Indicates an enabled safety alert is present
12 SS This flag asserts if an enabled safety fault is present.

0x0 = Indicates an enabled safety fault is not present

0x1 = Indicates an enabled safety fault is present
11-10 SEC1:SEC0 SEC1:0 indicate the present security state of the device.
.
When in SEALED mode, device configuration cannot be read or written and some commands are restricted.
.
When in FULLACCESS mode, unrestricted read and write access is allowed and all commands are accepted.

0x0 = 0: Device has not initialized yet.

0x1 = 1: Device is in FULLACCESS mode.

0x2 = 2: Unused.

0x3 = 3: Device is in SEALED mode.
9 RSVD0 Reserved
8 FET_EN This bit is set when the device is in autonomous FET control mode. The default value of this bit is set by the Settings:FET Options[FET_EN] bit in Data Memory upon exit of CONFIG_UPDATE mode. Its value can be modified during operation using the FET_ENABLE() subcommand.

0x0 = Device is not in autonomous FET control mode, FETs are only enabled through manual command.

0x1 = Device is in autonomous FET control mode, FETs can be enabled by the device if no conditions or commands prevent them being enabled.
7 POR This bit is set when the device fully resets. It is cleared upon exit of CONFIG_UPDATE mode. It can be used by the host to determine if any register configuration changes were lost due to a reset.

0x0 = Full reset has not occurred since last exit of CONFIG_UPDATE mode.

0x1 = Full reset has occurred since last exit of CONFIG_UPDATE and reconfiguration of any register settings is required.
6 SLEEP_EN This bit indicates whether or not SLEEP mode is allowed based on configuration and commands. The [[Power Config[SLEEP_EN]]] bit sets the default state of this bit. The host can send commands to enable or disable SLEEP mode based on system requirements. When this bit is set, the device can transition to SLEEP mode when other SLEEP criteria are met.

0x0 = SLEEP mode is disabled by the host.

0x1 = SLEEP mode is allowed when other SLEEP conditions are met.
5 CFGUPDATE This bit indicates whether or not the device is in CONFIG_UPDATE mode. It is set after the SET_CFGUPDATE() subcommand is received and fully processed. Configuration settings can be changed only while this bit is set.

0x0 = Device is not in CONFIG_UPDATE mode.

0x1 = Device is in CONFIG_UPDATE mode.
4 ALERTPIN This bit indicates whether the ALERT pin is asserted (pulled low).

0x0 = ALERT pin is not asserted (stays in hi-Z mode).

0x1 = ALERT pin is asserted (pulled low).
3 CHG This bit indicates whether the CHG driver is enabled.

0x0 = CHG driver is disabled.

0x1 = CHG driver is enabled.
2 DSG This bit indicates whether the DSG driver is enabled.

0x0 = DSG driver is disabled.

0x1 = DSG driver is enabled.
1 CHGDETFLAG This bit indicates the value of the debounced CHG Detector signal.

0x0 = CHG Detector debounced signal is low.

0x1 = CHG Detector debounced signal is high.
0 RSVD0 Reserved