SLUUCW8 October 2023 BQ27Z746
This command instructs the device to return Impedance Track related gauging information on MACData().
Status | Condition | Action |
---|---|---|
Activate | 0x0078 to AltManufacturerAccess() | Outputs 8 bytes of IT data values on MACData() in the following format: AAaaBBbbCCccDDdd where: AAaa: Flt Rem Q. Filtered remaining capacity (mAh) BBbb: Flt Rem E. Filtered remaining capacity (cWh) CCcc: Flt FCC Q. Filtered full charge capacity (mAh) DDdd: Flt FCC E. Filtered full charge capacity (cWh) |