SLUUCY8 December 2023 BQ77307
Class | Subclass | Name | Type | Min | Max | Default | Unit |
---|---|---|---|---|---|---|---|
Protections | Temperature | Overtemperature in Charge Protection Threshold | U1 | 0 | 255 | 55 | VREG18 / 359 |
Description: This parameter configures the threshold for the Overtemperature in Charge Protection. The protection is triggered when the TS pin voltage is detected below this threshold.
This sets the threshold detected at the TS pin from 0 to 255 in units of VREG18 / 359.