SLVAEB1A March 2020 – October 2021 TLV62568 , TLV62569 , TLV62585
Compared to SOT23-5, the SOT23-6 has better thermal performances with 10°C lower junction temperature and 12°C lower case temperature for the 2-A load. In addition, the SOT23-6 (DDC) package offers better efficiency at heavy loads as shown in Figure 4-5. For further detailed comparison between these two packages, see the SOT23 Package Thermal Consideration Application Report.