SLVK116 July 2022 TPS22919-Q1
This section provides the test conditions for the CE and RE measurements.
Table 1-1 shows EMI receiver settings for the conducted emission measurements.
Frequency Range | Resolution Bandwidth | Step Size |
---|---|---|
150 kHz–108 MHz | 120 kHz | 30 kHz |
Table 1-2 shows EMI receiver setting for the radiated emission measurements.
Frequency Range | Resolution Bandwidth | Step Size |
---|---|---|
150 kHz–30 MHz | 9 kHz | 2.25 kHz |
150 kHz–30 MHz | 120 kHz | 30 kHz |
200 kHz–1 GHz | 120 kHz | 30 kHz |