SLVK125A november   2022  – may 2023 TPS7H4001-SP

PRODUCTION DATA  

  1.   1
  2.   TPS7H4001-SHP Total Ionizing Dose (TID) (Rev. A)
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8. 5Revision History
  9.   A Appendix: HDR TID Report

Test Configuration and Condition

TPS7H4001-SHP HDR Units were stressed at 3 krad(Si) , 10 krad(Si), 30krad(Si), 30 krad(Si), 50 krad(Si) and 100 krad(Si) for biased and unbiased conditions.

Table 2-1 HDR ≥ 50–300 rad(Si)/s Biased Device Information (HDR)

Total samples: 42

Exposure Levels:
3 krad(Si) (5 samples)10 krad(Si) (5 samples)30 krad(Si) (5 samples)50 krad(Si) (5 samples)100 krad(Si) (22 samples)
#66, #67, #68, #69, #70#56, #57, #58, #59, #60#46, #47, #48, #49, #50#36, #37, #38, #39, #40#1- #6, #9 - #24
Table 2-2 HDR ≥ 50–300 rad(Si)/s Unbiased Device Information (HDR)
Total Samples: 25
Exposure Levels:
3 krad(Si) (5 samples)10 krad(Si) (5 samples)30 krad(Si) (5 samples)50 krad(Si) (5 samples)100 krad(Si) (5 samples)
#71, #72, #73, #74, #75#61, #62, #63, #64, #65#51, #52, #53, #54, #55#41, #42, #43, #44, #45#27, #28, #29, #30, #31