Device Details

Table 1-1 lists the device information used in the TID HDR characterization.

Table 1-1 Device and Exposure Details
TID HDR Details: 3, 10 , 30 , 50 and 100 krad(Si)
Package44-pin HTSSOP (DDW)
Quantity Tested

HDR:

5 biased and 5 unbiased units @ 3 krad(Si) levels

5 biased and 5 unbiased units @ 10 krad(Si) levels

5 biased and 5 unbiased units @ 30 krad(Si) levels

5 biased and 5 unbiased units @ 50 krad(Si) levels

22 biased and 5 unbiased units @ 100 krad(Si) levels

HDR Radiation FacilityCLAB,

Texas Instruments, Dallas, Texas

HDR Dose Level3 krad(Si), 10 krad(Si), 30 krad(Si), 50 krad(Si) 100 krad(Si)
HDR Dose Rate

200-250 rad(Si)/s ionizing radiation with increments

HDR Radiation SourceGamma source

At CLAB, Texas Instruments, Dallas, Texas

Irradiation and Test TemperatureAmbient, room temperature controlled to 24°C ±6°C per MIL-STD-883 and MIL-STD-750.
GUID-20221130-SS0I-GKKL-T0VQ-XLFHRCRKSJGZ-low.jpgFigure 1-1 TPS7H4001-SHP Devices Used in Exposure